Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-20211125 |
Title | PCN-20211125 TEC0850-03 Components Change |
Subject | Components Change |
Issue Date | 2021-11-29 |
Products Affected
This change affects all Trenz Electronic TEC0850 boards: TEC0850-03*.
Affected Product |
---|
TEC0850-03-BBEX1-A |
TEC0850-03-BBEX1-B |
TEC0850-03-BBEX1-C |
Changes
#1 Replaced LTST-C191KRKT (D1) by 19-213/R6C-AL1M2VY/3T
Type: BOM change
Reason: Part is NRND.
Impact: None.
#2 Replaced LTST-C191KGKT (D2, D3, D4) by 19-213/G6C-BM1N2/DT
Type: BOM change
Reason: Part is NRND.
Impact: None.
#3 Replaced BKP0603HS121-T (L1 ... L3, L5, L7, L10 ... L22) by MPZ0603S121HT000
Type: BOM change
Reason: Part is NRND and EOL announced.
Impact: None. DC resistance decreased from 150mOhm to 130mOhm, rated current increased from 0.85A to 1A.
#4 Replaced BSH103,215 (Q1, Q2, T1) by DMN3730U-7
Type: BOM change
Reason: Part is NRND.
Impact: None.
#5 Replaced 619 kOhm (R71) by 619 Ohm
Type: BOM change
Reason: Old resistor value is too high.
Impact: LED D3 is usable.
#6 Serialnumber (S/N) not assembled
Type: BOM change
Reason: Part is end of life.
Impact: Track it pad no more available.
#7 Replaced SiT8008AI-73-XXS-... (U6, U12) by SiT8008BI-73-XXS-...
Type: BOM change
Reason: Switch to actual revision. Revision A devices may be discontinued.
Impact: None.
Method of Identification
Changes above are applied to boards with serial number greater than 691580.
Production Shipment Schedule
From March 2022, after old stock is gone. If the new assembly variant is not suitable for your application and still the former one of the board is needed, please contact us.
Contact Information
If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at
- forum.trenz-electronic.de
- wiki.trenz-electronic.de
- support%trenz-electronic.de (subject = PCN-20211125)
phone
national calls: 05741 3200-0
international calls: 0049 5741 3200-0
Disclaimer
Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
This PCN follows JEDEC Standard J-STD-046.