This document provides a brief overview of the required board configuration (DIP switches, jumpers, etc.) for each supported module when used with the TE0706 carrier board. It describes the settings required for each module, including the boot mode configuration where applicable.
| DIP/Jumper/Button | TE0706-04 | TE07... | TE0821-02/TE0820-04 | TE08... | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| S1 |
* Close Dip (ON) will force to GND |
* Module CPLD Firmware depended | |||||||||||||||||||||||||||||||||||||||
| S2 | Reset, push button will force to GND | SoC POR_B via TPS supervisor | |||||||||||||||||||||||||||||||||||||||
| J9 | VBAT (optional) | powered only by carrier,PS battery backup supply pin | |||||||||||||||||||||||||||||||||||||||
| J10-J12 | VCCIO Power supply
(2-3=3.3V/1-2=1.8V) |
| |||||||||||||||||||||||||||||||||||||||
| J13 | SD Level Shifter (2-3=3.3V/1-2=1.8V) |
| |||||||||||||||||||||||||||||||||||||||
| TE0790 | USB to JTAG/UART Interface
default configuration for TE0706 | ||||||||||||||||||||||||||||||||||||||||
| CPLD Dependencies | no
| yes
| |||||||||||||||||||||||||||||||||||||||
| HW Revision Dependencies | yes, for older revisions:
| TE0821 Product Change Notifications yes
TE0820 Product Change Notifications yes
|