The Trenz Electronic TE0728 is a SoC module integrating a Xilinx Automotive Zynq-7020, 512 MByte DDR3 SDRAM with 16-Bit width, 16 MByte Flash Memory for configuration and operation, two 100 Megabit Ethernet transceivers, and powerful switch-mode power supplies for all on-board voltages. A large number of configurable I/O's is provided via rugged high-speed stacking strips.

All this in a compact 6 x 6 cm form factor, at the most competitive price.

All parts are at least automotive temperature range up to +105°C. The module operating temperature range depends on customer design and cooling solution. Please contact us for options.


PS Peripherals (on-board)

Chip/InterfaceICPS7 Peripheral
SPI FlashS25FL127SABMFV10QSPI016 MByte Flash
I2C EEPROM24xx64I2C08 KByte EEPROM
RTC I2CRV-3029I2C0
RTC InterruptRV-3029GPIO - MIO0
User LED
GPIO - MIO7

Mapping table for on-board IC to PS7 Peripherals

MIO PinMapped toPull up/downNotes
0GPIOUpRTC Interrupt
1QSPI0

2QSPI0Down
3QSPI0Down
4QSPI0DownOverride to up on base for bootmode change
5QSPI0Up
6QSPI0Down
7GPIODownOn-board LED
8CAN1 TXDDownCAN transceiver
9CAN1 RXD
CAN transceiver
10SPI1 MOSI

11SPI1 MISO

12SPI1 SCLK

13SPI1 SS0

14I2C0 SCLUpOn-board RTC, and EEPROM
15I2C0 SDAUpOn-board RTC, and EEPROM

Recommended Peripheral mapping for MIO Voltage bank 0.

PS7 UART

There is no fixed mapping for PS7 UART, if needed it can be mapped to free pins from MIO1 Bank or via EMIO to PL pins.

Recommended mapping for primary (console, debug) UART are MIO52, MIO53 for all cases when MIO1 is not used for off-board Gigabit ETH PHY.

PL Peripherals

Both Ethernet PHY IC's are connected to PL pins in Bank 34, all PHY IC pins are connected to FPGA pins, there is no sharing of signals for the two PHY's.

PUDC pin is connected with pull-up to 3.3V those pre-configuration pull-ups are disabled by default. Strapping resistor exist to change the PUDC mode.


PS and PL Banks

BankVCCIOB2B I/O PinsNotes
5003.3V0
501USER J2.4 B2B36MIO1 VREF is connected to resistor divider to support HSTL18
13USER J1.39 B2B48Differential routing
333.3V33Single ended routing
343.3V0Ethernet PHY's
353.3V42Single ended routing
03.3V4JTAG, note 3 pins can be used as input only from PL Fabric


Clock sources

ICDescriptionFrequencyUsed as
U14MEMS Oscillator33.3333 MHzPS7 PLL clock
U5MEMS Oscillator25 MHzEthernet PHY Clock
U7RTC (internal oscillator)32.768 KHzUsed by RTC, CLKOUT of RTC not connected


LED's

DesignatorColorConnected toActive LevelIO Standard
D9GreenDONELownot applicable
D8REDMIO7Highnot applicable
D4GreenPL pin V18HighLVCMOS33


XADC Usage

XADC PinConnected toNotes
AD0B2B
AD1B2B
AD3B2B
AD4B2B
AD5B2B
AD7PB2B
AD7NGND
AD8B2B
AD9B2B
AD10B2B
AD12B2B
AD13B2B
AD14B2B
AD15B2B

XADC is used with internal reference option.

Note the XADC capable pins are not routed differentially to the B2B connector. The performance and usability of the XADC must be evaluated.


Ethernet

There are two 100 MBit Extreme Temperature Ethernet PHY's DP83848YB on the board. Datasheet is available from TI, Literature number SNLS208H. Both PHY's are connected with all I/O Pins to FPGA Bank 34 (VCCIO = 3.3V). PHY Clock 25 MHz source is provided from MEMS Oscillator. All LED outputs have on-board pull-ups. Outputs to Magnetics have also required termination resistors on board.

Both PHY's must be operated in MII Mode, other modes are not supported. It is possible to use PS ENET0 or ENET1 via EMIO routing or Ethernet IP Cores implemented in PL Fabric.


ETH1ETH2PullupNotes
CTREFJ3.57J3.25
Magnetics center tap voltage
TD+J3.58J3.28on-board
TD-J3.56J3.26on-board
RD+J3.52J3.22on-board
RD-J3.50J3.20on-board
LED1J3.55J3.23on-board
LED2J3.53J3.21on-board
LED3J3.51J3.19on-board
POWERDOWN/INTL21R20on-chipIt is recommended to configure FPGA I/O as input with Pullup or as output driving 1 if Interrupt not used.
RESET_NM15R16on-chipIt is recommended to configure FPGA I/O as input with Pullup or as output (active low PHY Reset).

It is recommended to add IOB TRUE constraint for the MII Interface pins.

When connecting the PHY's to Zynq PS ETH0, ETH1 EMIO GMII Interfaces it is recommended to use GMII to MII Wrap IP Core. This IP core maps the EMIO GMII to external MII Interface.


Legal Notices

Data Privacy

Please also note our data protection declaration at https://www.trenz-electronic.de/en/Data-protection-Privacy

Document Warranty

The material contained in this document is provided “as is” and is subject to being changed at any time without notice. Trenz Electronic does not warrant the accuracy and completeness of the materials in this document. Further, to the maximum extent permitted by applicable law, Trenz Electronic disclaims all warranties, either express or implied, with regard to this document and any information contained herein, including but not limited to the implied warranties of merchantability, fitness for a particular purpose or non infringement of intellectual property. Trenz Electronic shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein.

Limitation of Liability

In no event will Trenz Electronic, its suppliers, or other third parties mentioned in this document be liable for any damages whatsoever (including, without limitation, those resulting from lost profits, lost data or business interruption) arising out of the use, inability to use, or the results of use of this document, any documents linked to this document, or the materials or information contained at any or all such documents. If your use of the materials or information from this document results in the need for servicing, repair or correction of equipment or data, you assume all costs thereof.

Copyright Notice

No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Trenz Electronic.

Technology Licenses

The hardware / firmware / software described in this document are furnished under a license and may be used /modified / copied only in accordance with the terms of such license.

Environmental Protection

To confront directly with the responsibility toward the environment, the global community and eventually also oneself. Such a resolution should be integral part not only of everybody's life. Also enterprises shall be conscious of their social responsibility and contribute to the preservation of our common living space. That is why Trenz Electronic invests in the protection of our Environment.

REACH, RoHS and WEEE

REACH

Trenz Electronic is a manufacturer and a distributor of electronic products. It is therefore a so called downstream user in the sense of REACH. The products we supply to you are solely non-chemical products (goods). Moreover and under normal and reasonably foreseeable circumstances of application, the goods supplied to you shall not release any substance. For that, Trenz Electronic is obliged to neither register nor to provide safety data sheet. According to present knowledge and to best of our knowledge, no SVHC (Substances of Very High Concern) on the Candidate List are contained in our products. Furthermore, we will immediately and unsolicited inform our customers in compliance with REACH - Article 33 if any substance present in our goods (above a concentration of 0,1 % weight by weight) will be classified as SVHC by the European Chemicals Agency (ECHA).

RoHS

Trenz Electronic GmbH herewith declares that all its products are developed, manufactured and distributed RoHS compliant.

WEEE

Information for users within the European Union in accordance with Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment (WEEE).

Users of electrical and electronic equipment in private households are required not to dispose of waste electrical and electronic equipment as unsorted municipal waste and to collect such waste electrical and electronic equipment separately. By the 13 August 2005, Member States shall have ensured that systems are set up allowing final holders and distributors to return waste electrical and electronic equipment at least free of charge. Member States shall ensure the availability and accessibility of the necessary collection facilities. Separate collection is the precondition to ensure specific treatment and recycling of waste electrical and electronic equipment and is necessary to achieve the chosen level of protection of human health and the environment in the European Union. Consumers have to actively contribute to the success of such collection and the return of waste electrical and electronic equipment. Presence of hazardous substances in electrical and electronic equipment results in potential effects on the environment and human health. The symbol consisting of the crossed-out wheeled bin indicates separate collection for waste electrical and electronic equipment.

Trenz Electronic is registered under WEEE-Reg.-Nr. DE97922676.


Error rendering macro 'page-info'

Ambiguous method overloading for method jdk.proxy244.$Proxy3589#hasContentLevelPermission. Cannot resolve which method to invoke for [null, class java.lang.String, class com.atlassian.confluence.pages.Page] due to overlapping prototypes between: [interface com.atlassian.confluence.user.ConfluenceUser, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject] [interface com.atlassian.user.User, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject]

Document Change History

DateRevisionAuthorsDescription
2015-05-10

Work in progress

All






  • No labels