The PCIexpress signal "PERST#" is forwarded to the SoM using signal CPLD_IO_1 (corresponding to B2B pin JB1-88.As long as RGPIO is not enabled, LED1 shows the inverted status of the PCIE_PERST signal (See USR LED).
CPLD_IO_1 <= (PCIE_PERST and M3_3VOUT); -- forward PCIE PERST# to SOM
As long as RGPIO is not enabled, LED1 shows the inverted status of the PCIE_PERST signal (See USR LED).
JTAG MUX
The folowing table summarizes the JTAG MUX. Only FMC and SoM JTAG have to be handled in the CPLD explicitly. Discrimination between Module CPLD and Module SOC/FPGA are done via hard connected dip switch. Same is true for TEF1002 CPLD MAX10.
...
Date | Document Revision | CPLD Firmware Revision | Supported PCB Revision | Authors | Description | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| REV03 | REV02 |
| Clearified PCIe PERST# | ||||||||||||||||||||||
v.14 | REV03 | REV02 | Martin Rohrmüller | initial version | |||||||||||||||||||||||