Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

...

LED description(need CPLD Firmware REV06 or newer):

BLUE Power LED  on enclosure
Status/ UserBlink SequenceComment
Power******** (slow blink)

Indicate board is powered off.

RGPIO controlledUser Defined

RGPIO 14 and 15, if RGPIO is active.

MIO40User Defined

MIO40, if RGPIO is deactivated

Main Power Switch is ON and Power Button is pressed first time

...

LED description (need CPLD Firmware REV06 or newer):

BLUE Power LED  on enclosure
Status/ UserBlink SequenceComment
Power******** (slow blink)

Indicate board is powered off.

RGPIO controlledUser Defined

RGPIO 14 and 15, if RGPIO is active.

MIO40User Defined

MIO40, if RGPIO is deactivated


Red HD LED  on enclosure
Status/ UserBlink SequenceComment
PS_INIT_B********

Indicates the PS is not initialized after a power-on reset (POR).

PS_ERROR_OUT*****ooo

The PS_ERROR_OUT signal is asserted for accidental loss of power, an error, or an exception in the PMU.

ERR_STAT****oooo

The PS_ERROR_STATUS indicates a secure lockdown state. Alternatively, it can be used by the PMU firmware to indicate system status.

RGPIO controlledUser Defined

RGPIO 16 and 17, if RGPIO is active

SC0User DefinedSC0 (PL IO), if RGPIO is deactivated

Notes

Most LEDs are CPLD Firmware dependents, see TEBF0808 Master CPLD and TEBF0808 Slave CPLD

...