Table of Contents |
---|
Warning |
---|
Do not change XMOD DIP-Switch settings on TEBF0808. Do not swap the XMOD adapters the one marked with green dot must be closer to the SoM |
...
Note |
---|
For all Starter Kit's shipped before 2017-06-21: Enclosure Power and HD LED was swapped on connector. See "Enclosure Power Button, Reset Button, HDD LED and Power LED" section for correct connection. |
Starter Kit is shipped with prebuilt Linux Example on SD. Newest version and sources are available on our download area: TE0808 Reference Designs
Connect main power and set power switch to on. See Main Power Enclosure Location
Warning |
---|
Do not change XMOD DIP-Switch settings on TEBF0808. Do not swap the XMOD adapters the one marked with green dot must be closer to the SoM |
...
For more information, see:TEBF0808, TEBF0808 Master CPLD and TEBF0808 Slave CPLD.
- Section is currently not complete -
No Power on Starter Kit.
Identification: FANs do not work, all LEDs are off.
Only some basics on TEBF0808 are powered on. This mode is used for CPLDs Firmware updates.
...
BLUE Power LED on enclosure | ||
---|---|---|
Status/ User | Blink Sequence | Comment |
Power | ******** (slow blink) | Indicate board is powered off. |
RGPIO controlled | User Defined | RGPIO 14 and 15, if RGPIO is active. |
MIO40 | User Defined | MIO40, if RGPIO is deactivated |
TE0808 will be powered on. System boots if boot mode is set correct and files are available.
...
Red HD LED on enclosure | ||
---|---|---|
Status/ User | Blink Sequence | Comment |
PS_INIT_B | ******** | Indicates the PS is not initialized after a power-on reset (POR). |
PS_ERROR_OUT | *****ooo | The PS_ERROR_OUT signal is asserted for accidental loss of power, an error, or an exception in the PMU. |
ERR_STAT | ****oooo | The PS_ERROR_STATUS indicates a secure lockdown state. Alternatively, it can be used by the PMU firmware to indicate system status. |
RGPIO controlled | User Defined | RGPIO 16 and 17, if RGPIO is active |
SC0 | User Defined | SC0 (PL IO), if RGPIO is deactivated |
Most LEDs are CPLD Firmware dependents, see TEBF0808 Master CPLD and TEBF0808 Slave CPLD
SI5345 NVM is not programmed on factory, so modified FSBL is needed to get running output CLKS.
It it possible to program NVM of the SI5345 2 times. With NVM configuration FSBL initialisation is not needed.
NVM can be programmed with Clock Builder Pro Field Programmer connected to connector J17. General documentation to do this are available on Application notes - Si5345
Starter Kit will be shipped with all cable connected.