IssuesDescriptionWorkaroundTo be fixed version
PCB REV01 only: IBERT no CLKPCB REV01 SI5338 is not preprogrammed and SI programming over MCS is disabled by default design and I2C is not connectedLoad test_board bitfile for REV01 and load IBERT design again without power off HWOpen Blockdesign and change IP "xlconstant_mcs_on_off" value from one to zero---

Requirements

Software

HTML
<!--
Add needed external Software
   -->

...

For general structure and of the reference design, see Project Delivery - AMD devices

Design Sources

TypeLocationNotes
Vivado<design name>/block_design
<design name>/constraints
<design name>/ip_lib
<design name>/firmware
Vivado Project will be generated by TE Scripts
SDK/HSI<design name>/sw_libAdditional Software Template for SDK/HSI and apps_list.csv with settings for HSI

...

Trenz Electronic provides a tcl based built environment based on Xilinx Design Flow.

See also:Vivado/SDK/SDSoCAMD Development Tools#XilinxSoftware-BasicUserGuides

The Trenz Electronic FPGA Reference Designs are TCL-script based project. Command files for execution will be generated with "_create_win_setup.cmd" on Windows OS and "_create_linux_setup.sh" on Linux OS.

TE Scripts are only needed to generate the vivado project, all other additional steps are optional and can also executed by Xilinx Vivado/SDK GUI.  For currently Scripts limitations on Win and Linux OS see: Project Delivery Currently limitations of functionality


  1. _create_win_setup.cmd/_create_linux_setup.sh and follow instructions on shell:
  2. Press 0 and enter for minimum setup
  3. (optional Win OS) Generate Virtual Drive or use short directory  for the reference design (for example x:\<design name>)
  4. Create Project
    1. Select correct device and Xilinx install path on "design_basic_settings.cmd" and create Vivado project with "vivado_create_project_guimode.cmd"
      Note: Select correct one, see TE Board Part Files
  5. Create HDF and export to prebuilt folder
    1. Run on Vivado TCL: TE::hw_build_design -export_prebuilt
      Note: Script generate design and export files into \prebuilt\hardware\<short dir>. Use GUI is the same, except file export to prebuilt folder
  6. Generate MCS Firmware (optional):
    1. Create SDK Project with TE Scripts on Vivado TCL: TE::sw_run_sdk
    2. Create "SCU" application
      Note: Select MCS Microblaze and SCU Application
    3. Select Release Built
    4. Regenerate App
  7. (optional) Copy "\\workspace\sdk\scu\Release\scu.elf" into  "\firmware\microblaze_mcs_0\"
  8. Regenerate Vivado Project or Update Bitfile only and "scu.elf"
  9. Copy MCS file with Bitfile into prebuilt folder
    1. Create SDK Project with TE Scripts on Vivado TCL: TE::sw_run_hsi

...

Xilinx documentation for programming and debugging: Vivado/SDK/SDSoC-Xilinx Software Programming and Debugging

QSPI

  1. Connect JTAG and power on PCB
  2. (if not done) Select correct device and Xilinx install path on "design_basic_settings.cmd" and create Vivado project with "vivado_create_project_guimode.cmd" or open with "vivado_open_project_guimode.cmd", if generated.
  3. Type on Vivado Console: TE::pr_program_flash_mcsfile -swapp
    Note: Alternative use SDK or setup Flash on Vivado manually
  4. Reboot (if not done automatically)

...