Input | Connected to | Frequency | Notes |
---|---|---|---|
IN0 | On-board Oscillator (U25) | 25.000000 MHz | - |
IN1 | B2B Connector pins J2-4, J2-6 (differential pair) | User | AC decoupling required on base |
IN2 | B2B Connector pins J3-66, J3-68 (differential pair) | User | AC decoupling required on base |
IN3 | OUT9 | User | Loop-back from OUT9 |
Output | Connected to | Frequency | Notes |
OUT0 | B2B Connector pins J2-3, J2-1 (differential pair) | User | Default off |
OUT1 | B230 CLK0 | User | Default off |
OUT2 | B229 CLK1 | User | Default off |
OUT3 | B228 CLK1 | User | Default off |
OUT4 | B505 CLK2 | User | Default off |
OUT5 | B505 CLK3 | User | Default off |
OUT6 | B128 CLK0 | User | Default off |
OUT7 | B2B Connector pins J2-713, J2-9 15 (differential pair) | User | Default off |
OUT8 | B2B Connector pins J2-137, J2-15 9 (differential pair) | User | Default off |
OUT9 | IN3 (Loop-back) | User | Default off |
XA/XB | Quartz (Y1) | 50.000 MHz | - |
...
Date | Revision | Contributors | Description | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
| ||||||||||||||||||||||||||
v.29 | John Hartfiel |
| |||||||||||||||||||||||||||
v.27 | John Hartfiel |
| |||||||||||||||||||||||||||
v.26 | John Hartfiel |
| |||||||||||||||||||||||||||
v.24 | Ali Naseri |
| |||||||||||||||||||||||||||
2017-11-13 | John Hartfiel |
| |||||||||||||||||||||||||||
2017-10-20 | v.21 | Ali Naseri |
| ||||||||||||||||||||||||||
2017-08-28 | v.15 | John Hartfiel |
| ||||||||||||||||||||||||||
2017-08-28 | v.14 | Jan Kumann |
| ||||||||||||||||||||||||||
2017-08-15 | v.12 | Vitali Tsiukala | Changed signals count in the B2B connectors table | ||||||||||||||||||||||||||
2017-08-15 | v.11 | John Hartfiel, Ali Naseri |
| ||||||||||||||||||||||||||
2017-02-06 | v.1 | Jan Kumann | Initial document |
...