Operating Conditions, Ratings and Dimensions

Recommended Operating Conditions

...

Absolute Maximum Ratings

Parameter
 ParameterMinimumMaximumUnit
Supply voltage range-0.35

V

Voltage at any bus terminal (CANH or CANL)-1414V
Operating temperature range-40150°C
Storage temperature-150°C

Recommended Operating Conditions

 MinimumMaximumUnit
Supply voltage33.6V
Operational free-air temperature-40125°C
Info

Refer to Texas Instruments TCAN337G product datasheet for additional information about conditions and ratings.

...