Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-20190103 |
Title | TE0630-01 to TE0630-02 Hardware Revision Change |
Subject | Trenz Electronic TE0630 Hardware Change |
Issue Date | 20190103 |
This change affects all variations of TE0630 carrier SoM of revision: TE0630-01
affected product | suggested upgrade |
---|---|
TE0630-01 | TE0630-02 |
Type: BOM Change
Reason: Improve fault rate
Impact: None
Type: Layout change
Reason: 2) Rerouted nets around U8, results in new track length for:
Impact: Applications with strict timings/length mached tracks have to consider new SoM track length. Signal Signal V3_IO_06 15.2475 mm (was 15.0047mm) Signal , Signal V3_IO_07 16.0151 mm (was 15.0452 mm)3)
4) PS_EN now via OR gate
Type: BOM Change
Reason: Improve fault rate
Impact: None
Type: Schematic Change
Reason: Improve fault rate
Impact: None
6) Fixed Footprint of U10 according to datasheet
7) Update from LIB
8) Rearranged Testpoints
9) Added Traceability Pad
10) Replaced S5 by smaller PB AN26337
Type:
Reason:
Type: BOM change
Reason: Former diodes obsolete
Impact: None
Type: PCB change
Reason: Improve production yield
Impact: None
Type: PCB change
Reason: Improve production yield
Impact: None
Type: Layout change
Reason: Optimize testing
Impact: Testpoints have new locations
Type: BOM change
Reason: Allow automated identification of module
Impact: None
Type: BOM change
Reason: Conflict with screws reported
Impact: Changed z-dimension has to be considered for housingsImpact:
The model code and revision number (e.g. TE0630-01 or TE0630-02) are printed on the top side of the PCB.
...