CompanyTrenz Electronic GmbH
PCN NumberPCN-20190103
Title

TE0630-01 to TE0630-02 Hardware Revision Change 

SubjectTrenz Electronic TE0630 Hardware Change
Issue Date

20190103

Products Affected

This change affects all variations of TE0630 carrier of revision: TE0630-01

affected product

suggested upgrade

TE0630-01

TE0630-02

1) Replaced U8 by EN6338QI

2) Rerouted nets around U8, results in new track length for:

    Signal V3_IO_06 15.2475 mm (was 15.0047mm)

    Signal V3_IO_07 16.0151 mm (was 15.0452 mm)

3) Replaced U5 by EN 6338QI

4) PS_EN now via OR gate

5) Replaced obsolete Diodes D1, D2 D4, by BAT54A

6) Fixed Footprint of  U10 according to datasheet

7) Update from LIB

8) Rearranged Testpoints

9) Added Traceability Pad

10) Replaced S5 by smaller PB AN26337


Changes

#1 

Type:

Reason:

Impact:


Method of Identification

The model code and revision number (e.g. TE0630-01 or TE0630-02) are printed on the top side of the PCB.

Production Shipment Schedule