Page History
...
Note |
---|
For all Starter Kit's shipped before 2017-06-21: Enclosure Power and HD LED was swapped on connector. See "Enclosure Power Button, Reset Button, HDD LED and Power LED" section for correct connection. |
Getting Started
Starter Kit is shipped with prebuilt Linux Example on SD. Newest version and sources are available on our download area: TE0808 Reference Designs
Connect main power and set power switch to on. See Main Power Enclosure Location
- Connect mini USB cable from XMOD with green dot to host PC. See XMODs Connection
- Insert SD-Card with pre-loaded content into SD-Card slot.
- Open Serial Console:
- COM Port: for correct number see device manager
- Speed:115200
- Press the Power on button on the enclosure. See Power Button, Reset Button, HDD LED and Power LED Enclosure Location
- Linux login:
- User Name:root
- Password:root
- TEBF0808 Getting Started - Basic note to start up Carrier with TE080x modules
Starter Kit Basic
Main Power Enclosure Location
...
For more information, see:TEBF0808, TEBF0808 Master CPLD and TEBF0808 Slave CPLD.
Starter Kit Status
- Section is currently not complete -
Main Power Switch is OFF
No Power on Starter Kit.
Identification: FANs do not work, all LEDs are off.
Main Power Switch is ON and Power Button is not pressed
Only some basics on TEBF0808 are powered on. This mode is used for CPLDs Firmware updates.
Identification: FANs do not work, some LEDs blinking.
LED description(need CPLD Firmware REV06 or newer):
...
Indicate board is powered off.
...
RGPIO 14 and 15, if RGPIO is active.
...
MIO40, if RGPIO is deactivated
Main Power Switch is ON and Power Button is pressed first time
TE0808 will be powered on. System boots if boot mode is set correct and files are available.
Identification: FANs do work, LEDs blinking states change.
...
...
.
...
RGPIO 14 and 15, if RGPIO is active.
...
MIO40, if RGPIO is deactivated
...
Indicates the PS is not initialized after a power-on reset (POR).
...
The PS_ERROR_OUT signal is asserted for accidental loss of power, an error, or an exception in the PMU.
...
The PS_ERROR_STATUS indicates a secure lockdown state. Alternatively, it can be used by the PMU firmware to indicate system status.
...
RGPIO 16 and 17, if RGPIO is active
...
Notes
Most LEDs are CPLD Firmware dependents, see TEBF0808 Master CPLD and TEBF0808 Slave CPLD
SI5345 NVM Programming
SI5345 NVM is not programmed on factory, so modified FSBL is needed to get running output CLKS.
It it possible to program NVM of the SI5345 2 times. With NVM configuration FSBL initialisation is not needed.NVM can be programmed with Clock Builder Pro Field Programmer connected to connector J17. General documentation to do this are available on Application notes - , see Si5345
Starter Kit Cable Connection
...