This Trenz Electronic Starter Kit consists of a TE0803 module on a TEBF0808 base board in Mini-ITX Enclosure. See shop link for detailed content.
...
...
Warning |
---|
Do not change XMOD DIP-Switch settings on TEBF0808. Do not swap the XMOD adapters, the one marked with a green dot must be closer to the SoM |
Note |
---|
ES devices are not included in all Vivado versions, for ES1 only: activate beta device see: FAQ - How can I activate beta devices? |
Note |
---|
For all Starter Kits shipped before 2017-06-21: Enclosure power and HD LED was swapped on connector. See "Enclosure Power Button, Reset Button, HDD LEDand Power LED" section for correct connection. |
Starter Kit is shipped with prebuilt Linux Example on SD. Newest version and sources are available in our download area: TE0803 Reference Designs
Connect main power and set power switch to on. See Main Power Enclosure Location
Warning |
---|
Do not change XMOD DIP-Switch settings on TEBF0808. Do not swap the XMOD adapters, the one marked with a green dot must be closer to the SoM |
...
TE0790-02
(with green dot)
...
DIP-Schalter | S4 |
---|---|
S4.1 | OFF |
S4.2 | OFF |
S4.3 | OFF |
S4.4 | ON |
...
DIP-Schalter | S5 |
---|---|
S5.1 | ON |
S5.2 | ON |
S5.3 | OFF |
S5.4 | OFF |
...
DIP-Schalter | S1 |
---|---|
S1.1 | ON |
S1.2 | OFF |
S1.3 | OFF |
S1.4 | OFF |
...
DIP-Schalter | S1 |
---|---|
S1.1 | ON |
S1.2 | OFF |
S1.3 | OFF |
S1.4 | OFF |
Note: with CPLD Firmware REV06 or newer, S4.4 can be set to OFF, to save power, if Starter Kit is powered off with Power Button.
For more information see: TEBF0808, TEBF0808 Master CPLD and TEBF0808 Slave CPLD.
- Section is currently not complete -
No power on Starter Kit.
Identification: FANs do not work, all LEDs are off.
Only some basics on TEBF0808 are powered on. This mode is used for CPLDs Firmware updates.
Identification: FANs do not work, some LEDs blinking.
LED description (need CPLD Firmware REV06 or newer):
...
Indicate board is powered off.
...
RGPIO 14 and 15, if RGPIO is active.
...
MIO40, if RGPIO is deactivated
TE0803 will be powered on. System boots, if boot mode is set correct and files are available.
Identification: FANs do work, LEDs blinking states change.
LED description(need CPLD Firmware REV06 or newer):
...
Indicate board is powered off.
...
RGPIO 14 and 15, if RGPIO is active.
...
MIO40, if RGPIO is deactivated
...
Indicates the PS is not initialized after a power-on reset (POR).
...
The PS_ERROR_OUT signal is asserted for accidental loss of power, an error, or an exception in the PMU.
...
The PS_ERROR_STATUS indicates a secure lockdown state. Alternatively, it can be used by the PMU firmware to indicate system status.
...
RGPIO 16 and 17, if RGPIO is active
...
Most LEDs are CPLD Firmware dependents, see TEBF0808 Master CPLD and TEBF0808 Slave CPLD
Starter Kit will be shipped with all cable connected.
...