- There is a possible risk of burns due to hot surfaces while running the Board. This e.g. might be caused by an overcurrent at the motor outputs.
- The product is only allowed to be used in horizontal position on a non conducting and non inflameable surface.
- All externaly connected power sources must be SELV protected (Separated or safety extra-low voltage).
- This product is only allowed to be used in dry an indoor environment.
- This product is not allowed to be used unattended by an electrical specialist.
- During operations it is not allowed to change the wiring or mechanical setup.
- For set up the wiring switch off or disconnect all external power suplies.
- The mechanical setup must ensure that the whole test setup can not be dropped to the floor or moved accidently.
Signals, Interfaces and Pins
...
- Disconnecting the reference motor board TEC0060 by unmounting its screws and the encoder cable from J10
- Mounting the deliverd 30A Fuse to the connectors J5 and J6 with the deliverd M5 screws
- For lower supply current requirements, caused by the power rating of the used motor, a fuse with a lower and suitable current rating in the supply wiring is recommended.
- Connecting with a cable lugs the +DC 5..48V to J6 and the corresponding GND to J1.
- The cable length is limited to 3m.
- Connection the three motor phases to J2 (A), J3 (B) and J4 (C).
- The cable length is limited to 3m.
- Optional: connect the encoder wires to J10 or J11
and set jumper field according to signal specification: differential or single ended
See section TODO for details
...