anchorTable_power_management
titlePower Management


Port/Signaldepends on (RGPIO not aktive)additional when RGPIO aktiveDescriptionRemark
EN_PERM3_3VOUTrgpio_out_data_i(15)Enable perepherie power 3V3_PERvia PWR_EN_Signal
FMC_PWR_setM3_3VOUTrgpio_out_data_i(16)Signal indicate FMC enable
EN_FMCFMC_PWR_set and NOT(FMC_PRSNT_M2C_L)rgpio_out_data_i(17)Enable switched 3.3V FMC power
FAN_FMC_ENFMC_PWR_set and NOT(FMC_PRSNT_M2C_L) -Enable FMC FAN
EN_FMC_VADJ(FMC_PWR_set and NOT(FMC_PRSNT_M2C_L)) or USR0-Enable IO power FMC_VADJUSR0 dip switch S3-2 can be used to enable FMC_VADJ when no FMC installed
FMC_PG_C2M(PG_FMC_VADJ and M3FMC_PWR_3VOUTset)-Indicate that all FMC related powers are up


...