Download a PDF version of this document.

Overview

The Trenz Electronic TEMB0005 is a carrier for the module TEM00005. The carrier is equipped with an ethernet socket, a FTDI JTAG/UART to USB 2.0 interface, three low speed and one high speed CRUVI connectors and a PMOD IO connector.

Refer to http://trenz.org/temb0005-info for the current online version of this manual and other available documentation.

Key Features

  • Supported SoM
    • TEM0005 - Microsemi SmartFusion 2 SoC
  • On Board
    • JTAG/UART to USB 2.0 converter (FTDI)
    • 2x Oscillators - SoM and FTDI programmer
    • 2x Push Buttons - reset and user
    • 4x LEDs - green, user
    • 1x LEDs - green, supply good
    • 1x LEDs - red, SoM power rails good
  • RAM/Storage
    • 2 KB EEPROM - programmer configuration
  • Interface
    • Trenz Electronic SoM 5.2 x 7.6 1x B2B (Samtec SS5) socket
    • 1x RJ45 Ethernet socket with LEDs
    • CRUVI connectors - 1x HS + LS, 2x LS
    • 1x Micro USB 2.0 connector - SoM JTAG and UART
    • 6x pin header - SoM SPI
    • 1x Pmod IO header
  • Power
    • Single Rail 5 V power supply
    • Supply protection - reverse polarity, over and under voltage
  • Dimension
    • 115 mm x 70 mm

Block Diagram


TEMB0005 block diagram

Main Components

 

TEMB0005 main components
  1. JTAG/UART to USB 2.0 converter, U1
  2. Barrel jack (2.1 mm) - 5 V supply, J4
  3. Micro USB 2.0 type B - JTAG/UART, J2
  4. RJ45 Ethernet, J1
  5. CRUVI HS, J5
  6. CRUVI LS, J6, J7, J8
  7. 6x pin header - SoM SPI, J3
  8. PMOD IO header, J9
  9. Buttons - reset, S1 - user, S2
  10. LEDs user - green, D1, D2, D3, D4
  11. LED carrier power - green, D5
  12. LED SoM power good - red, D8
  13. Module B2B socket (Samtec SS5), J11

Initial Delivery State

Storage device

Content

Notes

EEPROMProgrammer configuration

Do not overwrite!

Initial delivery state of programmable devices

Signals, Interfaces and Pins

Connectors

Connector Type

Designator

Interface

IO count

Notes

B2B

J11

CRUVI HS

24x SE / 12x DIFF


B2B

J11

CRUVI LS

24x SE


B2B

J11

ETH MDI

2x DIFF


B2B

J11

FTDI BUS IO

2x SE


B2B

J11

PMod IO

8x SE / 4x DIFF


B2B

J11

SPI

4x SE


B2B

J5

CRUVI HS

24x SE / 12x DIFF


Dual wipe socket 2.0 mm

J6

CRUVI LS

8x SE


Dual wipe socket 2.0 mm

J7

CRUVI LS

8x SE


Dual wipe socket 2.0 mm

J8

CRUVI LS

8x SE


RJ45J1ETH MDI2x DIFF


Micro USB type B

J2

FTDI BUS IO

1x DIFF


PMod

J9

PMod IO

8x SE / 4x DIFF


Pin header 2.54 mm

J3

SPI

4x SE


Board connectors

Test Points

Test

Point

REV02

REV01

Signal

Top

Bottom

Notes

Signal

TP1

x



GOLDEN

TP2

x



JTAGSEL

TP3

x



PG_DCDC

TP4

x



VADJ

TP5

x



PROBE_B

TP6

x



PROBE_A

TP7

x



3.3V

Not used

TP8

x



EN_VADJ

Not used

TP9

x



PG_3.3V

Not used

TP10

x



PG_VADJ

Not used

TP11


x


VADJ

Not used

TP12


x


3.3V

Not used

Test points information

On-board Peripherals

Chip/Interface

Designator

Connected to

Notes

JTAG/UART converter

U1

  • SoM B2B J11
  • EEPROM U3
  • Oscillator U4
  • Micro USB type B J2


EEPROM

U3

  • JTAG/UART converter U1


Oscillator

U4

  • JTAG/UART converter U1

12 MHz

Oscillator

U8

  • SoM B2B J11

30 MHz

On-board peripherals

Configuration and System Control Signals

Control signals represent hardware defined logic states, for final state consider the firmware and reference designs.

Control Signals and Buses

Signal Name

Connector.Pin

Direction1)

Description

JTAGSEL

J11.9

OUT

Test point for JTAG controller selection.

PROBE_B / PROBE_A

J11.81 / J11.83

OUT

Test point for SmartDebug Live Probe feature.

M_RESET

J11.11

OUT

Reset the SoM.

BUTTON

J11.121

OUT

User button.

GOLDEN

J11.148

OUT

Test point for SPI master mode status.

SEL_VADJ

J11.108

IN

Voltage Rail VADJ DCDC converter voltage control.

EN_VADJ

J11.110

IN

Test point for Voltage Rail VADJ DCDC converter enable.

JTAG ( TDI / TDO / TCk / TMS )

J11.8 / J11.10 / J11.12 / J11.14

Signal dependent

SoM SoC JTAG

UART ( UART1_RXD / UART1_TXD )

J11.115 / J11.117

Signal dependent

SoM SoC UART

SPI ( SC_CLK / SC_SDO / SC_SDI / SC_SS )

J11.100 / J11.102 / J11.104 / J11.106

J3.6 / J3.3 / J3.4 / J3.5

Signal dependent

SoM SoC SPI

SPI ( DI / DO / SEL / SCK )

J11.125 / J11.127 / J11.129 / J11.131

J5.51 / J5.53 / J5.55 / J5.59

Signal dependent

CRUVI SPI

I2C ( SMB_ALERT / SMB_SDA / SMB_SCL )

J11.94 / J11.116 / J11.118

Signal dependent

CRUVI HS I2C

LED1 / LED2 / LED3 / LED4

J11.126 / J11.119 / J11.73 / J11.90

IN

User LEDs

ETH1_LED1 / ETH1_LED0

J11.152 / J11.154

IN

Ethernet status LEDs

1) Direction:

    • IN: Input from the point of view of this board.

    • OUT: Output from the point of view of this board.

    • INOUT: Bidirectional signal.
    • Signal dependent: A Signal can have different functions and directions as part of a Bus.
Control signals and buses

Buttons

Button

Signal

Voltage level

Function

Low

high

S1M_RESET

pressed

unpressed

Reset the SoM. No pull up resistor on TEMB0005.

S2BUTTON

pressed

unpressed

User button. Pulled up on TEMB0005.

Buttons

Power and Power-On Sequence

Power Rails

Power Rail Name / Schematic Name

Connector.Pin

Direction 1)

Notes

5VIN_unpro

J4.1

IN

Carrier power supply rail.

5VIN

J5.60 / J6.12 / J7.12 / J8.12

OUT

Supply from carrier to headers and connectors.

3.3V

J11.1 / J11.2 / J11.3 / J11.4

J5.4 / J6.10 / J7.10 / J8.10

J9.6 / J9.12

J3.1

OUT

Supply from carrier to SoM, headers and connectors.

VADJ


J5.36 / J11.22

OUT

Power supply for external use.

1) Direction:

    • IN: Input from the point of view of this board.
    • OUT: Output from the point of view of this board.
Power rails

Recommended Power up Sequencing


SequenceNet nameRecommended Voltage RangePull-up/downDescriptionNotes
0---Configuration signal setup.See Configuration and System Control Signals.
15VIN_unpro

5 V (± 5 %)

-

Power supply. 

Carrier power supply.

Power sequencing

Board to Board Connectors

5.2 x 7.6 cm SoM Zynq modules use three Samtec Razor Beam LP Terminal Strip (ST5) on the bottom side.
  • 3x REF-192552-02 (160-pins)
    • ST5 Mates with SS5

5.2 x 7.6 cm SoM Zynq carrier use three Samtec Razor Beam LP Socket Strip (SS5) on the top side.

  • 3x REF192552-01 (160-pins)
    • SS5 Mates with ST5

Technical Specifications

Absolute Maximum Ratings *)

Power Rail Name/ Schematic NameDescriptionMinMaxUnit

5VIN_unpro

Carrier supply rail.

0

12

V
Absolute maximum ratings

*) Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under "Recommended Operating Condition". Exposure to absolute-maximum rated conditions for extended periods may affect device reliability.

Recommended Operating Conditions

Temperature range

Trenz Electronic classifies modules into temperature range categories by subsumption of its component data (PCB, ICs, connectors, passive components). The temperature ranges are values for ambient air temperature and do not reflect the junction temperature of individual components.

The categories are:

  • Modules with commercial (C) temperature grade are equipped with components that cover at least the ambient temperature range of 0 °C to 70 °C.
  • Modules with extended (E) temperature grade are equipped with components that cover at least the ambient temperature range of 0 °C to 85 °C.
  • Modules with industrial (I) temperature grade are equipped with components that cover at least the ambient temperature range of -40 °C to 85 °C.

These categories do not take into account the entire custom system consisting of:

  • Customer SoC design. The allowed main SoC temperature range is specified from the vendor by junction temperature using corresponding classes (C, E, I). See vendor documentation.
  • Cooling solution, active and or passive cooling.
  • Climate or environmental conditions besides ambient temperature range.
  • Module orientation, neighbouring assemblies, neither other heat sources nor the SoC as heat source to other components.

Classification of the module can be looked up here: Article Number Information i.e.: TExxxx-xx-xx'I'xx, the 'I' indicates that all components are at least in Industrial temperature class.

The temperature of individual components should not exceed the specified range due to self-heating or heating by adjacent components. The actual operating temperature range will depend on the customer design, usage, environment and cooling solution. Consult Cooling Solutions for more information.

Voltage rails

The following table aims to be generic for all variants. The voltage ranges are consistent across assembly variants, but exceptions are possible (custom request).

ParameterMinMaxUnitsReference Document

5VIN_unpro

4.75

5.25VRefer to schematic.
Recommended operating conditions

Physical Dimensions

  • Module size: 115 mm × 70 mm.  Please download the assembly diagram for exact numbers.

  • Mating height with standard connectors: 4 mm.

  • PCB thickness: 1.674 mm ± 10 %.

Physical dimension

Currently Offered Variants 

Trenz shop TEMB0005 overview page
English pageGerman page
Trenz Electronic shop overview

Revision History

Hardware Revision History

Hardware revision number can be found on the PCB board together with the module model number separated by the dash.

Board hardware revision number


Date

Revision

Changes

Documentation Link

2020-08

REV02

  1. Page numbering changed for schematic
  2. SCH and PCB components updated from libraries
  3. L3 BKP0603HS121-T (EOL) changed to MPZ1608S221A
  4. Change connections for pins:
    - pin U2:2 was connected to net "D_P", now connected to net "DL_P"
    - pin U2:3 was connected to net "D_N", now connected to net "DL_N"
  5. U4 SiT8008AI-73-XXS-12.000000E (EOL) changed to SiT8008BI-73-XXS-12.000000E
  6. D6, D7 WE-TVS-824013 (EOL) changed to WE-TVS-824015043
  7. PM1-PM6 FIDU-DOT-small changed to FIDU-DOT-mini
  8. Change connections for pins:
    - pin J11:121 was connected to net "LED2", now connected to net "BUTTON"
    - pin J11:119 was connected to net "BUTTON", now connected to net "LED2"
  9. DCDC U7 EN6347QI (EOL) changed to MPM3860GQW-Z
  10. DCDC U6 EP53A7HQI (EOL) changed to MPM3834CGPA
  11. Added pages legal notices, power overview
  12. Added system overview
  13. CRUVI mounting holes and connectors J5-J8 moved to the left by 0.6mm
  14. Mounting holes and B2B connector J11 for module TEM0005 moved to the left by 1.6mm
  15. Mounting holes of PCB on the right side moved to the left by 16.6mm (in one line with CRUVI mounting holes now)
  16. TP7 - TP12 added
  17. R8 49R9 changed to 33R, R9 10k to 12k. C1, C2 0201 6.3V to 0402 25V, C32 4.7uF to 10uF, C33 470nF to 100nF. BOM optimisation
  18. R37 added as optional
  19. UKCA and RoHS logos added

  20. T3 and T4 BSH103BK changed to BSS138LT1G

REV2

PCN

2020-05

REV01

  • Initial release

REV1

Hardware revision history

Document Change History

DateRevisionContributorDescription

Kilian Jahn

  • Updated to TRM template 4.3.9
  • Update TRM to board revision 04

2021-01-14

v.34

Martin Rohrmüller

  • Initial Release

--

all

  • --
Document change history.

Disclaimer

Data Privacy

Please also note our data protection declaration at https://www.trenz-electronic.de/en/Data-protection-Privacy

Document Warranty

The material contained in this document is provided “as is” and is subject to being changed at any time without notice. Trenz Electronic does not warrant the accuracy and completeness of the materials in this document. Further, to the maximum extent permitted by applicable law, Trenz Electronic disclaims all warranties, either express or implied, with regard to this document and any information contained herein, including but not limited to the implied warranties of merchantability, fitness for a particular purpose or non infringement of intellectual property. Trenz Electronic shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein.

Limitation of Liability

In no event will Trenz Electronic, its suppliers, or other third parties mentioned in this document be liable for any damages whatsoever (including, without limitation, those resulting from lost profits, lost data or business interruption) arising out of the use, inability to use, or the results of use of this document, any documents linked to this document, or the materials or information contained at any or all such documents. If your use of the materials or information from this document results in the need for servicing, repair or correction of equipment or data, you assume all costs thereof.

Product Disclaimer

Products (incl. Software and Firmware) are exclusively designed, manufactured, and distributed for industrial applications. They are not intended, authorized, or certified for use in critical safety applications, medical devices, aerospace, nuclear, life-support, traffic-control, military, or other environments where malfunction or failure could result in personal injury, death, or significant property or environmental damage.

Trenz Electronic GmbH (“Manufacturer”) excludes any liability for inappropriate use in such contexts. The Customer bears all responsibility for verifying suitability and compliance with applicable regulations when deploying in any critical-use scenario. The Customer also agrees to indemnify and hold harmless the Manufacturer from any third-party claims or liabilities arising from such use.

Copyright Notice

No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Trenz Electronic.

Technology Licenses

The hardware / firmware / software described in this document are furnished under a license and may be used /modified / copied only in accordance with the terms of such license.

Environmental Protection

To confront directly with the responsibility toward the environment, the global community and eventually also oneself. Such a resolution should be integral part not only of everybody's life. Also enterprises shall be conscious of their social responsibility and contribute to the preservation of our common living space. That is why Trenz Electronic invests in the protection of our Environment.

REACH, RoHS and WEEE

REACH

Trenz Electronic is a manufacturer and a distributor of electronic products. It is therefore a so called downstream user in the sense of REACH. The products we supply to you are solely non-chemical products (goods). Moreover and under normal and reasonably foreseeable circumstances of application, the goods supplied to you shall not release any substance. For that, Trenz Electronic is obliged to neither register nor to provide safety data sheet. According to present knowledge and to best of our knowledge, no SVHC (Substances of Very High Concern) on the Candidate List are contained in our products. Furthermore, we will immediately and unsolicited inform our customers in compliance with REACH - Article 33 if any substance present in our goods (above a concentration of 0,1 % weight by weight) will be classified as SVHC by the European Chemicals Agency (ECHA).

RoHS

Trenz Electronic GmbH herewith declares that all its products are developed, manufactured and distributed RoHS compliant.

WEEE

Information for users within the European Union in accordance with Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment (WEEE).

Users of electrical and electronic equipment in private households are required not to dispose of waste electrical and electronic equipment as unsorted municipal waste and to collect such waste electrical and electronic equipment separately. By the 13 August 2005, Member States shall have ensured that systems are set up allowing final holders and distributors to return waste electrical and electronic equipment at least free of charge. Member States shall ensure the availability and accessibility of the necessary collection facilities. Separate collection is the precondition to ensure specific treatment and recycling of waste electrical and electronic equipment and is necessary to achieve the chosen level of protection of human health and the environment in the European Union. Consumers have to actively contribute to the success of such collection and the return of waste electrical and electronic equipment. Presence of hazardous substances in electrical and electronic equipment results in potential effects on the environment and human health. The symbol consisting of the crossed-out wheeled bin indicates separate collection for waste electrical and electronic equipment.

Trenz Electronic is registered under WEEE-Reg.-Nr. DE97922676.