You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Current »

Download PDF version of this document.

CompanyTrenz Electronic GmbH
AVN NumberAVN-20220701.0 
TitleAVN-202207010.0 TEB0911 RTC does not work
SubjectInformation about RTC usage
Issue Date

2022-07-01


Products Affected

Affected Product

TEB911-01-*
TEB911-02-*
TEB911-03-*
TEB911-04-*

Notes

The HW wiring for the RTC is incorrect. This leads to the fact that the RTC initializes, but the time does not change.

RTC time can be tested with "hwclock --test"

Patch

Problem can be solved with following HW changes:

  1. Remove Y2 and R47

  2. Solder Resistor 0R (0603) on place of Y2;

  3. Solder Resistor 3M9 (0402) on place of R47;

  4. Solder Crystal SC12S-12.5PF20PPM above Resistor 3M9


Procedure to fix RTC issue


Production Shipment Schedule

We are issuing a new revision o TEB0911 and will make the necessary changes to future modules.


Method of Identification

  • The module revision number is printed on the top side of the PCB:


Contact Information

If you have any questions related to this AVN, please contact Trenz Electronics Technical Support at

Disclaimer

Any projected dates in this AVN are based on the most current product information at the time this AVN is being issued, but they may change due to unforeseen circumstances.  For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.

This AVN follows JEDEC Standard J-STD-046.