TE0630 provides user I/O signals connected to B2B connectors J4 and J5. There are 3 types of user I/O signals:

  • Single ended;
  • Differential pairs (each pair is configurable as 2 single-ended digital I/Os);
  • Differential pairs, which can be used as clock inputs (each pair can be used as usual differential pair or 2 single-ended digital I/Os)

The table below shows user I/O count for J4 and J5.

 

 

J4

J5

Total

Single ended

12

18

30

Differential

18

16

34

Differential (clock)

4

2

6

Total

56

54

110

User I/O count by connector

 

The table below shows user I/O divided by VCCIO supply voltage.

 

VCCIO0

3.3V

Total

Single ended

1

29

30

Differential

18

16

34

Differential (clock)

4

2

6

Total

45

65

110

User I/O count by VCCIO


  • No labels