You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 35 Next »

TE0320 is provided with a slide switch S2.
Slide switch S2 conditions the value of signal PS_EN.
In this way, S2 conditionally/unconditionally enables the 1.2 V and 2.5 V power rails.


Figure 33: Slide switch S2 (angle view).


Figure 34: Slide switch S2 schematic.


Figure 35: When slide switch S2 = FX2 PON, signal PS_EN is set to signal FX2_PS_EN driven by the EZ-USB FX2LP USB FX2 microcontroller under user control.

When S2 is turned on (FX2 PON), the 1.2 V and 2.5 V power rails are controlled by the USB (EZ-USB FX2LP USB FX2) microcontroller. At start-up, the USB microcontroller switches off the 1.2 V and 2.5 V power rails and starts up the module in low-power mode. After enumeration, the USB microcontroller firmware switches the 1.2 V and 2.5 V power rails on, if enough current is available from the USB bus.

When S2 is turned off, the 1.2 V and 2.5 V power rails are always enabled.

S2 position

Default position

Effect on 1.2 V and 2.5 V rails

FX2 PON (on) 

(tick)

1.2 V and 2.5 V rails controlled by USB FX2 microcontroller (signal FX2_PS_EN)

PS_EN = FX2_PS_EN = 1 or 0

PON (off)

(error)

1.2 V and 2.5 V rails always enabled (PS_EN = 1)

PS_ENFX_PS_EN = 1 or 0

Table 14: Slide switch S2 settings overview (1.2 V and 2.5 V rails only).

Signal FX2_PS_EN

To command signal FX2_PS_EN, read the reference firmware code.
IOD = 0x03; // Enable PS_EN and disable PROG_B
OED = 0x03; // Configure PS_EN and PROG as outputs

 

Port D Pin
Alternate
Function
Alternate Function
is Selected By...
Alternate Function
is Described in...
PD.7:0FD[15:8]

IFCFG1 = 1 and

any WORDWIIDE bit = 1
Slave FIFOs chapter 9 on page 99

Table from EZ-USB(R) Technical Reference Manual (EZ-USB_TRM.pdf).

Signal PS_EN

  • Signal PS_EN enables (1) or disables (0) power rails 2.5V and 1.2V.

    Figure 36: Power rails 2.5V and 1.2V could be enabled/disabled by signal PS_EN.
  • Power-rail 3.3V is not controlled by signal PS_EN and is unconditionally enabled. 
      
    Figure 37: Power rails 3.3V could not be enabled/disabled by signal PS_EN.

VCCIO assembly options

According to the corresponding assembly option, power rail VCCCIO0 can depend or not on the 2.5V power rail.

Figure 37: example of VCCIO0 assembly not dependent on 2.5V power rail. The other way is also possible.

Slide Switch S2 = FX2 PON 

When slide switch S2 is in the left position ( = FX2 PON : power rails conditionally on depending on signal FX2_PS_EN), signal PS_EN is set to signal FX2_PS_EN (PS_EN = FX2_PS_EN) driven by the EZ-USB FX2LP USB FX2 microcontroller under user control (IOD and OED of fw.c).

Figure 38: S2 on position FX2 PON (PS_EN = FX2_PS_EN = 1 or 0 ).  

  1. Dynamic full power operation (PS_EN = 1): when the EZ-USB FX2LP USB FX2 microcontroller sets signal PS_EN = FX2_PS_EN = high, power rails 2.5V and 1.2V are enabled.
    This setting can be useful for .
  2. Dynamic low power operation (PS_EN = 0): when the EZ-USB FX2LP USB FX2 microcontroller resets signal PS_EN = FX2_PS_EN = low, the following components are switched off:
    • FPGA core logic (1.2V)
    • DDR SDRAM (2.5V)
    • FPGA bank 3 (2.5V)
    • VREF (2.5V)
    • VCCCIO0 (2.5V) FPGA bank 0 (if R131+R132- assembly)

Slide Switch S2 = PON 

Full power operation (PS_EN = 1): when slide switch S2 is in the right position (PON = power rails unconditionally on), signal PS_EN is set to power rail 3.3V. Thus power rails 2.5V and 1.2V are unconditionally enabled.


Figure 39: S2 on position PON (PS_EN ≠ FX2_PS_EN = x; PS_EN = high ). 

Summary table

Table 14 summarizes all switching options implied by slide switch S2 and firmware signal FX2_PS_EN (under the standard assembly option).

power rail

S2= PON
(PS_EN = 1)

(PS_EN ≠ FX2_PS_EN)
(Full power)

S2 = FX2 PON and
PS_EN = FX2_PS_EN = 1

(Dynamic full power)

S2 = FX2 PON and
PS_EN = FX2_PS_EN = 0

(Dynamic low power)

1.2V

on

on

off

2.5V

on

on

off

VCCCIO0 (= 2.5V)
R131+R132- assembly (1)

on

on

off

VCCCIO0 (= 3.3V)
R131-R132+ assembly (2)

on

on

on

(1) R131 soldered / R132 unsoldered

(2) R131 unsoldered / R132 soldered

Table 40: Slide switch S2 settings overview ( 1.2V , 2.5V, VCCIO0).

 Alternate Assembly Options for Slide Switch S2

Slide switch S2 can be replaced by one resistors in the following cases:

  • cost sensitive applications
  • applications where just one position of S2 is required
  • application where switching of S2 is not allowed.

Assembly option when resistor R17 not populated and R19 populated is equivalent to slide switch S2 permanently set to PON.


Figure 41: assembly option: S2 = PON.

Assembly option when resistor R17 populated and R19 not populated is equivalent to slide switch S2 permanently set to FX2 PON.


Figure 42: Assembly option: S2 = FX2 PON.

 

Any other assembly options of R17 and R19 are not allowed.

  • No labels