This command stops both the test started by FX22MB_REG0_START_TX (0x02, read test) and FX22MB_REG0_START_RX (0x03, write test).
This MicroBlaze command does not require the use of SET_INTERRUPT before and GET_INTERRUPT after. It is instead required to send this command after
the data transmission (form the USB FX2 to the host computer or from the host computer to the USB FX2) is ended. See 4.3.3 FX22MB_REG0_START_TX and 4.3.4 FX22MB_REG0_START_RX for more information.
This command writes data (12 bytes) to the requested I2C address.
Byte |
Value |
Description |
1 |
0xAD |
I2C_WRITE command ID |
2 |
0x3F |
I2C Address |
3 |
0x0C |
FX2_Parameters.I2C_BYTES=0x0C |
4 |
0x00 |
- |
5 |
0x00 |
- |
6 |
0x00 |
- |
7 |
0x04 |
MB_Commands.FX22MB_REG0_STOP |
From 8 to 64 |
- |
Not used |
Table 35: FX22MB_REG0_STOP MicroBlaze command.
Reply packet doesn't contain any usable information.