Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-20211125 |
Title | PCN-20211125 TEC0850-03 EOL Components Change |
Subject | EOL Components Change |
Issue Date | 20211125 |
Products Affected
This change affects all Trenz Electronic TE0850 SoMs: TE0850-03*.
Affected Product | Replacement |
---|---|
TE0850-03-BBEX1-A | TE0850-03-BBEX1-A |
TE0850-03-BBEX1-B | TE0850-03-BBEX1-B |
TE0850-03-BBEX1-C | TE0850-03-BBEX1-C |
Changes
#1 Replaced LTST-C191KRKT (D1) by 19-213/R6C-AL1M2VY/3T
Type: Schematic change
Reason: Part is EOL.
Impact: None.
#2 Replaced LTST-C191KGKT (D2, D3, D4) by 19-213/G6C-BM1N2/DT
Type: Schematic change
Reason: Part is EOL.
Impact: None.
#3 Replaced BKP0603HS121-T (L1, L2, L3, L5, L7, L10, L11, L12, L13, L14, L15, L16, L17, L18, L19, L20, L21, L22) by MPZ0603S121HT000
Type: Schematic change
Reason: Part is EOL.
Impact: None.
#4 Replaced BSH103,215 (Q1, Q2, T1) by DMN3730U-7
Type: Schematic change
Reason: Part is EOL.
Impact: None.
#5 Replaced 619 kOhm (R71) by 619 Ohm
Type: Schematic change
Reason: Part is EOL.
Impact: LED D3 should be usable.
#6 Removed Serialnumber (S/N)
Type: Schematic change
Reason: Part is EOL.
Impact: None.
#7 Replaced SiT8008AI-73-XXS-12.000000E (U6) by SiT8008BI-73-XXS-12.000000E
Type: Schematic change
Reason: Part is EOL.
Impact: None.
#8 Replaced SiT8008AI-73-XXS-52.000000E (U12) by SiT8008BI-73-XXS-52.000000E
Type: Schematic change
Reason: Part is EOL.
Impact: None.
Method of Identification
Production Shipment Schedule
From XXXXX, after old stock is gone. If the new revision is not suitable for your application and still the former revision of the board is needed, please contact us.
Contact Information
If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at
- forum.trenz-electronic.de
- wiki.trenz-electronic.de
- support%trenz-electronic.de (subject = PCN-JJJJMMDD)
phone
national calls: 05741 3200-0
international calls: 0049 5741 3200-0
Disclaimer
Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
This PCN follows JEDEC Standard J-STD-046.