CompanyTrenz Electronic GmbH
PCN NumberPCN-20220228
TitleTE0720-03 to TE0720-04 Hardware Revision Change
SubjectHardware Revision Change
Issue Date

JJJJMMDD

Products Affected

This change affects all Trenz Electronic TE0720 SoMs of revision 03.

Affected Product

Replacement
TE0720-03-*TE0720-04-*


TE0720-03-2IFC5(inactiv but sold)
TE0720-03-2IFC7(inactiv but sold)
TE0720-03-1CFC1(inactiv not sold)
TE0720-03-1QC9(inactiv but sold)
TE0720-03-2IFC9(inactiv not sold)
TE0720-03-L1IFN(inactiv but sold)
TE0720-03-1QC10(inactiv but sold)
TE0720-03-1QFC(inactiv but sold)
TE0720-03-1CRV1(inactiv not sold)
TE0720-03-1CRV2(inactiv not sold)
TE0720-03-62I120M(inactiv not sold)
TE0720-03-62I32-V1(inactiv but sold)
TE0720-03-1QFC1(inactiv but sold)
TE0720-03-62I330M(activ and sold)
TE0720-03-61C530A(activ and sold)
TE0720-03-61Q43GA(inactiv not sold)
TE0720-03-61Q86KL(activ and sold)
TE0720-03-62I33-V1TE0720-03-62I33-V1
TE0720-03-1QFA-V2(inactiv not sold)
TE0720-03-S001(inactiv not sold)
TE0720-03-61C530AS(active only offer)
TE0720-03-31C33MA(active and sold)
TE0720-03-61C33MA(active and sold)
TE0720-03-61Q33MA(active and sold)
TE0720-03-61C33MAS(active and sold)
TE0720-03-S005
TE0720-03-S006C1
TE0720-03-S007C1
TE0720-03-S008C1
TE0720-03-S009C1
TE0720-03-61Q33ML
TE0720-03-61Q43MA
TE0720-03-62I33MA
TE0720-03-62I33MAN
TE0720-03-62I33ML
TE0720-03-64I63MA
TE0720-03-S003C1
TE0720-03-S004
TE0720-03-62I12NA
TE0720-03-62I33NA
TE0720-03-61Q42NA
TE0720-03-S010
TE0720-03-14S-1CY
TE0720-03-1CFAY
TE0720-03-2IFAY
TE0720-03-31C33MAY
TE0720-03-61C33FAY
TE0720-03-61C530AY
TE0720-03-61C33MAY
TE0720-03-61Q42GAY????
TE0720-03-62I33MAY
TE0720-03-S011
TE0720-03-S012
TE0720-03-S013
TE0720-03-S014
TE0720-03-S015
TE0720-03-S016
TE0720-03-S017
TE0720-03-S018
TE0720-03-S019
TE0720-03-1QFY
TE0720-03-61Q33MAY
TE0720-03-1QFAY
TE0720-03-S020
TE0720-03-S021
TE0720-03-S022
TE0720-03-S023
TE0720-03-S024
TE0720-03-S025C1
TE0720-03-S026
TE0720-03-S027

Changes

#14 Auxiliary information has been added on Samtec B2B connectors page.

Type: DOC Change

Reason: Improve connector documentation.

Impact: None.

#14 Added legal notices.

Type: DOC Change

Reason: Clarify copyright issues.

Impact: None. Schematic page number changes.

#14 Added revision change history.

Type: DOC Change

Reason: Record revision changes.

Impact: None. Schematic page number changes.

#14 Added system overview.

Type: DOC Change

Reason: Display system information.

Impact: None. Schematic page number changes.

#14 Added power diagram.

Type: DOC Change

Reason: Display supply power information.

Impact: None. Schematic page number changes.

#14 Change power page.

Type: DOC Change

Reason: Improve power documentation.

Impact: None. Schematic page number changes.


#1 Replace EN6347QI (U1) by MPM3840GQV-Z

Type: Schematic Change

Reason: Enpirion DCDCs are discontinued.

Impact: None.

#2 Replace EP53F8QI (U2, U3) by MPM3834CGPA

Type: Schematic Change

Reason: Enpirion DCDCs are discontinued.

Impact: None. Maximum continuous output current of DCDC increased from 1.5 A to 3 A on each rail.

#3 Replace TPS27082LDDCR (Q1) by MP5077GG-Z

Type: Schematic Change

Reason: Part is EOL.

Impact: None.

#4 Added power supervisor BD39040MUF (U27)

Type: Schematic Change

Reason: Improve the voltage rail supervision.

Impact: None.

#5 Connect BD39040MUF "PG_All" - signal U27.15 to system controller U19.C12 with pull-up resistor R67.

Type: Schematic Change

Reason: Power Supervisor connection.

Impact: None.

#6 Connect BD39040MUF "WDEN" - signal U27.13 to system controller U19.C6 with pull-down resistor R80.

Type: Schematic Change

Reason: Power Supervisor connection.

Impact: None.

#7 Connect BD39040MUF "WDIN" - signal U27.14 to system controller U19.N8.

Type: Schematic Change

Reason: Power Supervisor connection.

Impact: None.

#8 Connect BD39040MUF "WDOUT" - signal U27.16 to system controller U19.M3.

Type: Schematic Change

Reason: Power Supervisor connection.

Impact: None.

#9 Signal MIO8 (U5.E5) connected to system controller (U19.N7).

Type: Schematic Change

Reason: Enable boundary scan for MIO bank 1.

Impact: None.

#10 Added pull-down resistors R64 for net "ON_1V0".

Type: Schematic Change

Reason: Default pull-down option to avoid floating states.

Impact: None.

#11 Added pull-down resistors R65 for net "ON_1V8".

Type: Schematic Change

Reason: Default pull-down option to avoid floating states.

Impact: None.

#12 Power supervisor U26 connected to 3.3VIN power rail (was 3.3V).

Type: Schematic Change

Reason: Avoid high-signal-state at U26 manual reset pin 3 without powered supervisor.

Impact: None.

#13 Added protection diode D3 to U26.3 (#MR input).

Type: Schematic Change

Reason: Avoid voltage high-signal-state at U26 manual reset pin 3 without powered supervisor.

Impact: None.


#15 Changed PCB layout of power supplies.

Type: PCB Change

Reason: DCDCs with new footprints needs to be used.

Impact: None.

#16 Added option to install Heatsink SuperGrip (c).

Type: PCB Change

Reason: Improve optional cooling solution.

Impact: None.

#17 Added capacitors C7 and C8 (100uF, 1V).

Type: PCB Change

Reason: Improve decoupling for "1V" voltage rail.

Impact: None.

#18  Changed PCB layout of Samtec B2B signals.

Type: PCB Change

Reason: Result of this PCN changes.

Impact: The length of the tracks has been changed. Pinot of Samtec B2B connectors is not affected. Changed trace length has to be taken into account in existing designs. Please, check if change in trace length still matches your requirements. Adaption of carrier may be necessary.

Method of Identification

The model code and revision number of the module (e.g. TE0720-03 or TE0720-04) are printed on the top side of the PCB for revision 04 and is missing for revision 03.

Production Shipment Schedule

The new revision 04 will be shipped from October 2022. If the new revision is not suitable for your application and still the former revision of the board is needed, please contact us.


Contact Information

If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at

Disclaimer

Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances.  For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.

This PCN follows JEDEC Standard J-STD-046.