You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

CompanyTrenz Electronic GmbH
PCN NumberPCN-20230620
TitleTE0710-02 to TE0710-03 Hardware Revision Change
SubjectHardware Revision Change
Issue Date

2023-07-01

Products Affected

This change affects all Trenz Electronic TE0710 SoMs: TE0710-02*.

(ED: Check table!)

Affected Product

Replacement
TE0710-02-100-2CFTE0710-03-72C21-A
TE0710-02-35-2CFTE0710-03-42C21-A
TE0710-02-42I21-ATE0710-03-42I21-A
TE0710-02-72I21-ATE0710-03-72I21-A

Changes

#1 Changed DDR3L SDRAM (U12) from MEM4G08D3EABG-125 to IS43TR85120BL-125KBLI. ???? I can not find it in schematics!!!

Type: BOM change

Reason: 

Impact:

#1 Changed load switch from TPS27082LDDCR (Q1) to MP5077GG-Z and adapted circuit.

Type: Schematic Change

Reason: BOM Optimization.

Impact: None. Increased current output capability. Minor changes in electrical characteristics.

#3 Changed clock (U9) from SiT8008AI-73-XXS-25.000000E to SiT8008BI-73-XXS-25.000000E.

Type: Schematic Change

Reason: Use new clock revision.

Impact: None.

#4 Changed power supervisor TPS3805H33DCKR (U23) to STM6710LWB6F and adapted circuits.

Type: Schematic Change

Reason: Improved power monitoring.

Impact: Improved power monitoring circuit by supervising additional voltage rails. If monitored voltages are out of range signal "PG_ALL" is triggered.

#5 Changed ferrid bead BKP0603HS121-T (L1...L6) to MPZ0603S121HT000.

Type: Schematic Change

Reason: EOL of Component.

Impact: None.

#6 Changed DCDC EN6347QI (U1) to MPM3860GQW-Z and adapted power circuit.

Type: Schematic Change

Reason: EOL of Component.

Impact: None. Increased current output capability. Minor changes in electrical characteristics.

#7 Changed DCDC EN5311QI (U10, U11) to MPM3834CGPA and adapted power circuit.

Type: Schematic Change

Reason: EOL of Component.

Impact: None. Increased current output capability. Minor changes in electrical characteristics.

#8 Added diode D4 between signal nets "INIT" and "PROG_B".

Type: Schematic Change

Reason: Keep FPGA in reset while signal "PROG_B" is low during initial power-up.

Impact: None.

#9 Added pull-up resistor R50 for signal net "PROG_B".

Type: Schematic Change

Reason: Remove floating signal situations and enable signal measurement.

Impact: None. Firmware reflects it but custom firmware needs to be updated by customer.

#10 Added testpoints TP1...TP11.

Type: Schematic Change

Reason: Improve voltage measuring possibilities.

Impact: None.

#11 Changed size from 0805 to 0603 for capacitor C44.

Type: Schematic Change

Reason: BOM Optimization.

Impact: None.

#12 Changed fiducials to standard fiducial type.

Type: Schematic Change

Reason: Use standard fiducials.

Impact: None.

#13 Updated components from library.

Type: Schematic Change

Reason: Use latest component data.

Impact: None.

#14 Updated documentation on page "B2B_Connectors".

Type: Documentation Update

Reason: Documentation improvement.

Impact: None.

#15 Updated overview.

Type: Documentation Update

Reason: Documentation improvement.

Impact: None.

#16 Updated power overview.

Type: Documentation Update

Reason: Documentation improvement.

Impact: None.

#17 Update revision history.

Type: Documentation Update

Reason: Documentation improvement.

Impact: None.

Method of Identification

The revision number is shown on the top side of the PCB.

Production Shipment Schedule

From january 2024, after old stock is gone. If the new revision is not suitable for your application and still the former revision of the board is needed, please contact us.


Contact Information

If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at

Disclaimer

Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances.  For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.

This PCN follows JEDEC Standard J-STD-046.

  • No labels