Download PDF version of this document.
Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-20200806 |
Title | TE0724-03 to TE0724-04 Hardware Revision Change |
Subject | Hardware Revision Change |
Issue Date | 2020-09-02 |
This change affects all Trenz Electronic TE0724 SoMs of revision 03: TE0724-03-*.
Affected Product | Replacement |
---|---|
TE0724-03-* | TE0724-04-* |
Type: BOM change
Reason: Pullups too weak in similar configurations.
Impact: None.
Type: Schematic change
Reason: EEPROM was constantly write protected or had to be patched.
Impact: EEPORM is not write protected, no patch needed. For enabling write protection R72 can be assembled instead of R79.
Type: BOM change
Reason: This parts were identified as critical for very high ambient temperatures.
Impact: None. Parts are specified for up to 125°C and therefore the module can cope better with higher ambient temperatures.
Type: PCB change
Reason: Request for usage of BGA cooler with clip on mounting frame.
Impact: BGA cooler can now be used without any interferring components. No other impact, all Routing length have been perserved.
Type: BOM change
Reason: Part is end of life.
Impact: Track it pad no more available.
Type: Documentation change
Reason: Increase awarness of legal usage.
Impact: None.
Type: PCB change
Reason: Improve production yield.
Impact: None.
The revision number is printed on both sides of the PCB.
The new revison 04 is available from Novembre 2020, after old Stock is gone. If you still need revision 03 please contact us.
If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at
phone
national calls: 05741 3200-0
international calls: 0049 5741 3200-0
Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
This PCN follows JEDEC Standard J-STD-046.