Company | Trenz Electronic GmbH |
---|---|
PCN Number | PCN-20230920 |
Title | TE0818-01 to TE0818-02 Hardware Revision Change |
Subject | Hardware Revision Change |
Issue Date | 2023-11-01 |
This change affects all Trenz Electronic TE0818 SoMs: TE0818-01*.
Affected Product | Changes | Replacement |
---|---|---|
TE0818-01-9BE21-AZ | #1...#12 | TE0818-02-9BE81-A |
TE0818-01-BBE21-AZ | #1...#12 | TE0818-02-BBE81-A |
TE0818-01-6BE21-A | #2...#12 | TE0818-02-6BE81-A |
TE0818-01-9BE21-A | #2...#12 | TE0818-02-9BE81-A |
TE0818-01-9GI21-A | #2...#12 | TE0818-02-9GI81-A |
TE0818-01-9GI21-AK | #2...#12 | TE0818-02-9GI81-AK |
TE0818-01-9GI21-AS | #2...#12 | TE0818-02-9GI81-AS |
TE0818-01-BBE21-A | #2...#12 | TE0818-02-BBE81-A |
TE0818-01-BGI21-A | #2...#12 | TE0818-02-BGI81-A |
TE0818-01-9GI81-A | #3...#12 | TE0818-02-9GI81-A |
TE0818-01-9GI81-AK | #3...#12 | TE0818-02-9GI81-AK |
TE0818-01-BBE81-A | #3...#12 | TE0818-02-BBE81-A |
TE0818-01-BBE81-AK | #3...#12 | TE0818-02-BBE81-AK |
Type: BOM Change
Reason: TPS82085SIL availability.
Impact: Minor changes in electrical characteristics.
Type: BOM change
Reason: BOM Optimization.
Impact: New DDR timing needs to be considered in customer design. Firmware reflects it but custom firmware needs to be updated by customer.
Type: Schematic Change
Reason: Improve stability.
Impact: None. Improved stability.
Type: Schematic Change
Reason: VTT decoupling improvement.
Impact: Improved VTT voltage rail reliabililty.
Type: Schematic Change
Reason: Protect manual reset pin.
Impact: None.
Type: Schematic Change
Reason: Enable DDR4 test improvement.
Impact: None.
Type: Schematic Change
Reason: Improve voltage measuring possibilities.
Impact: None.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None.
Type: Schematic Change
Reason: BOM Optimization.
Impact: None.
Type: PCB Change
Reason: Result of changes above.
Impact: Changed trace length have to be taken into account in existing designs. The trace length for new revision will be available in TE081x series pinout generator. Please check if change in trace length still matches your requirements. Adaption of carrier may be necessary.
Type: Documentation Update
Reason: Documentation improvement.
Impact: None.
The revision number is printed on the top side of the PCB.
This change takes place with immediate effect. If the new revision is not suitable for your application and still the former revision of the board is needed, please contact us.
If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at
phone
national calls: 05741 3200-0
international calls: 0049 5741 3200-0
Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
This PCN follows JEDEC Standard J-STD-046.