The usage of this steps is at owner's own risk. Trenz Electronic is not liable for damage caused by following this steps.

Short Description

The TE0722 is configured to boot from flash with JTAG in cascade mode. If you configure the TE0722 Flash with wrong Boot.bin (for ex. you use Xilinx default or wrong FSBL. Or you insert additional applications file into the boot.bin without necessary workarounds), the Zynq - PS is running into a state, in which the FPGA and the Flash is not accessible via JTAG.This workaround set the FPGA in JTAG independent mode on startup to erase the corrupt flash content.

Procedure

For this case, you can try the following steps without guarantee for success:

  1.  Disconnect TE0722 and close all Xilinx Programs.

 

References

  • Zynq-7000 All Programmable SoC - Technical Reference Manual (UG585):Page 167-Section 6.25 Boot Mode Pin Settings
  • TE0722 Schematics, Download page:TE0722
  • No labels