You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

The usage of this steps is at owner's own risk. Trenz Electronic is not liable for damage caused by following this steps.

 

Short Description

The TE0722 is configured to boot from flash with JTAG in cascade mode. If you configure the TE0722 Flash with wrong Boot.bin (for ex. you use Xilinx default or wrong FSBL. Or you insert additional applications file into the boot.bin without necessary workarounds), the Zynq - PS is running into a state, in which the FPGA and the Flash is not accessible via JTAG.This workaround set the FPGA in JTAG independent mode on startup to erase the corrupt flash content.

Procedure

For this case, you can try the following steps without guarantee for success:

  1. Close all Xilinx Programs.
  2. Power off TE0722
  3. Bridge S25FL127S Pin 7 temporary with GND to set Boot Mode to independent JTAG (See picture xxx).
  4. Power on TE0722
  5. Open SDK
  6. Disconnect you GND bridge to Pin 7
  7. (optional) Try to get access to the FPGA with SDK Debugger (Is this not possible, flash programming is also not possible)
  8. Try to program Flash with valid Boot.Bin, if programming failed try again from step 1.

GND-Bridge to S25FL127S Pin 7

 

 

 

References

  • No labels