Download PDF version of this document.
Table of Contents
Trenz Electronic TE0728 is an automotive-grade FPGA module integrating a Xilinx Automotive Zynq-7020 FPGA, two 100 Mbit Ethernet transceivers (PHY) , 512 MByte DDR3L SDRAM, 16 MByte Flash memory for configuration and operation, and powerful switching-mode power supplies for all on-board voltages. Numerous configurable I/Os are provided via rugged high-speed strips.
Within the complete module only Automotive components are installed.
All this in a compact 6 x 6 cm form factor, at the most competitive price.
Refer to http://trenz.org/te0728-info for the current online version of this manual and other available documentation.
Depending on the customer design, additional cooling might be required.
Storage device name | Content | Notes |
---|---|---|
.. | .. | .. |
OTP Flash area | Empty | Not programmed. |
FPGA bank number and number of I/O signals connected to the B2B connector:
FPGA Bank | B2B Connector | I/O Signal Count | Voltage Level | Notes |
---|---|---|---|---|
13 | JM1 | 48 | VCCO_13 | |
500 | JM1 | 4 | 3.3V | |
33 | JM3 | 34 | 3.3V | |
35 | JM3 | 20 | 3.3V | |
35 | JM2 | 22 | 3.3V | |
501 | JM2 | 38 | VMIO1 | MIO1 VREF is connected to resistor divider to support HSTL18 |
JTAG access to the Xilinx XA7Z020 FPGA through B2B connector JM2.
JTAG Signal | B2B Pin |
---|---|
TMS | JM2-12 |
TDI | JM2-10 |
TDO | JM2-8 |
TCK | JM2-6 |
PS7 UART
There is no fixed mapping for PS7 UART, if needed it can be mapped to free pins from MIO1 Bank or via EMIO to PL pins.
Recommended mapping for primary (console, debug) UART are MIO52, MIO53 for all cases when MIO1 is not used for off-board Gigabit ETH PHY.
Chip/Interface | IC | PS7 Peripheral | |
---|---|---|---|
SPI Flash | S25FL127SABMFV10 | QSPI0 | 16 MByte Flash |
I2C EEPROM | 24xx64 | I2C0 | 8 KByte EEPROM |
RTC I2C | RV-3029 | I2C0 | |
RTC Interrupt | RV-3029 | GPIO - MIO0 | |
User LED | GPIO - MIO7 |
On-board QSPI flash memory S25FL127SABMFV10 is used to store initial FPGA configuration. Besides FPGA configuration, remaining free flash memory can be used for user application and data storage. All four SPI data lines are connected to the FPGA allowing x1, x2 or x4 data bus widths. Maximum data rate depends on the selected bus width and clock frequency used.
Designator | Color | Connected to | Active Level | IO Standard |
---|---|---|---|---|
D9 | Green | DONE | Low | not applicable |
D8 | RED | MIO7 | High | LVCMOS33 |
D4 | Green | PL pin V18 | High | LVCMOS33 |
There are two 100 MBit Extreme Temperature Ethernet PHY's DP83848YB on the board. Datasheet is available from TI, Literature number SNLS208H. Both PHY's are connected with all I/O Pins to FPGA Bank 34 (VCCIO = 3.3V). PHY Clock 25 MHz source is provided from MEMS Oscillator. All LED outputs have on-board pull-ups. Outputs to Magnetics have also required termination resistors on board.
Both PHY's must be operated in MII Mode, other modes are not supported. It is possible to use PS ENET0 or ENET1 via EMIO routing or Ethernet IP Cores implemented in PL Fabric.
ETH1 | ETH2 | Pullup | Notes | |
---|---|---|---|---|
CTREF | J3-57 | J3-25 | Magnetics center tap voltage | |
TD+ | J3-58 | J3-28 | on-board | |
TD- | J3-56 | J3-26 | on-board | |
RD+ | J3-52 | J3-22 | on-board | |
RD- | J3-50 | J3-20 | on-board | |
LED1 | J3-55 | J3-23 | on-board | |
LED2 | J3-53 | J3-21 | on-board | |
LED3 | J3-51 | J3-19 | on-board | |
POWERDOWN/INT | L21 | R20 | on-chip | It is recommended to configure FPGA I/O as input with Pullup or as output driving 1 if Interrupt not used. |
RESET_N | M15 | R16 | on-chip | It is recommended to configure FPGA I/O as input with Pullup or as output (active low PHY Reset). |
It is recommended to add IOB TRUE constraint for the MII Interface pins.
When connecting the PHY's to Zynq PS ETH0, ETH1 EMIO GMII Interfaces it is recommended to use GMII to MII Wrap IP Core. This IP core maps the EMIO GMII to external MII Interface.
add drawIO object here: Attention if you copy from other page, objects are only linked.
Create DrawIO object here: Attention if you copy from other page, objects are only linked.
Power Rail Name | B2B Connector JM1 Pin | B2B Connector JM2 Pin | B2B Connector JM3 Pin | Direction | Notes |
---|---|---|---|---|---|
VIN | 1,3 | - | - | Input | |
3.3 | 19 | 2, 4 | - | Output | |
1.8 | 39 | 5 | - | Output | |
Parameter | Min | Max | Units | Reference Document |
---|---|---|---|---|
Parameter | Min | Max | Units | Reference Document |
---|---|---|---|---|
Trenz shop TE0xxx overview page | |
---|---|
English page | German page |
Date | Revision | Note | PCN | Documentation Link |
---|---|---|---|---|
- | 01 | Prototypes | - | - |
Hardware revision number is printed on the PCB board next to the module model number separated by the dash.
Date | Revision | Contributor | Description |
---|---|---|---|
| |||
-- | all |
|
Please also note our data protection declaration at https://www.trenz-electronic.de/en/Data-protection-Privacy
The material contained in this document is provided “as is” and is subject to being changed at any time without notice. Trenz Electronic does not warrant the accuracy and completeness of the materials in this document. Further, to the maximum extent permitted by applicable law, Trenz Electronic disclaims all warranties, either express or implied, with regard to this document and any information contained herein, including but not limited to the implied warranties of merchantability, fitness for a particular purpose or non infringement of intellectual property. Trenz Electronic shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein.
In no event will Trenz Electronic, its suppliers, or other third parties mentioned in this document be liable for any damages whatsoever (including, without limitation, those resulting from lost profits, lost data or business interruption) arising out of the use, inability to use, or the results of use of this document, any documents linked to this document, or the materials or information contained at any or all such documents. If your use of the materials or information from this document results in the need for servicing, repair or correction of equipment or data, you assume all costs thereof.
No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Trenz Electronic.
The hardware / firmware / software described in this document are furnished under a license and may be used /modified / copied only in accordance with the terms of such license.
To confront directly with the responsibility toward the environment, the global community and eventually also oneself. Such a resolution should be integral part not only of everybody's life. Also enterprises shall be conscious of their social responsibility and contribute to the preservation of our common living space. That is why Trenz Electronic invests in the protection of our Environment.
REACH
Trenz Electronic is a manufacturer and a distributor of electronic products. It is therefore a so called downstream user in the sense of REACH. The products we supply to you are solely non-chemical products (goods). Moreover and under normal and reasonably foreseeable circumstances of application, the goods supplied to you shall not release any substance. For that, Trenz Electronic is obliged to neither register nor to provide safety data sheet. According to present knowledge and to best of our knowledge, no SVHC (Substances of Very High Concern) on the Candidate List are contained in our products. Furthermore, we will immediately and unsolicited inform our customers in compliance with REACH - Article 33 if any substance present in our goods (above a concentration of 0,1 % weight by weight) will be classified as SVHC by the European Chemicals Agency (ECHA).
RoHS
Trenz Electronic GmbH herewith declares that all its products are developed, manufactured and distributed RoHS compliant.
WEEE
Information for users within the European Union in accordance with Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment (WEEE).
Users of electrical and electronic equipment in private households are required not to dispose of waste electrical and electronic equipment as unsorted municipal waste and to collect such waste electrical and electronic equipment separately. By the 13 August 2005, Member States shall have ensured that systems are set up allowing final holders and distributors to return waste electrical and electronic equipment at least free of charge. Member States shall ensure the availability and accessibility of the necessary collection facilities. Separate collection is the precondition to ensure specific treatment and recycling of waste electrical and electronic equipment and is necessary to achieve the chosen level of protection of human health and the environment in the European Union. Consumers have to actively contribute to the success of such collection and the return of waste electrical and electronic equipment. Presence of hazardous substances in electrical and electronic equipment results in potential effects on the environment and human health. The symbol consisting of the crossed-out wheeled bin indicates separate collection for waste electrical and electronic equipment.
Trenz Electronic is registered under WEEE-Reg.-Nr. DE97922676.