Products Affected
This change affects all Trenz Electronic TE0850 boards: TE0850-03*.
Affected Product | Replacement |
---|---|
TE0850-03-BBEX1-A | TE0850-03-BBEX1-A |
TE0850-03-BBEX1-B | TE0850-03-BBEX1-B |
TE0850-03-BBEX1-C | TE0850-03-BBEX1-C |
Changes
#1 Replaced LTST-C191KRKT (D1) by 19-213/R6C-AL1M2VY/3T
Type: BOM change
Reason: BOM optimisation.
Impact: None.
#2 Replaced LTST-C191KGKT (D2, D3, D4) by 19-213/G6C-BM1N2/DT
Type: BOM change
Reason: BOM optimisation.
Impact: None.
#3 Replaced BKP0603HS121-T (L1 ... L3, L5, L7, L10 ... L22) by MPZ0603S121HT000
Type: BOM change
Reason: BOM optimisation.
Impact: None.
#4 Replaced BSH103,215 (Q1, Q2, T1) by DMN3730U-7
Type: BOM change
Reason: BOM optimisation.
Impact: None.
#5 Replaced 619 kOhm (R71) by 619 Ohm
Type: BOM change
Reason: BOM optimisation.
Impact: LED D3 is usable.
#6 Not fitted Serialnumber (S/N)
Type: BOM change
Reason: BOM optimisation.
Impact: None.
#7 Replaced SiT8008AI-73-XXS (U6, U12) by SiT8008BI-73-XXS
Type: BOM change
Reason: BOM optimisation, revision update.
Impact: None.
Method of Identification
Boards with serial number greater than 691580.
Production Shipment Schedule
From March 2021, after old stock is gone. If the new assembly variant is not suitable for your application and still the former one of the board is needed, please contact us.
Contact Information
If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at
- forum.trenz-electronic.de
- wiki.trenz-electronic.de
- support%trenz-electronic.de (subject = PCN-20211125)
phone
national calls: 05741 3200-0
international calls: 0049 5741 3200-0
Disclaimer
Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances. For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.
This PCN follows JEDEC Standard J-STD-046.