The Trenz Electronic TEP0001 is an industrial-grade dual CAN FD transceiver with Pmod interface.
...
- Digilent Pmod interface compatible
- Dual CAN FD PHY's (CAN0 and CAN1)
- Texas Instruments TCAN337G
- Up to 5Mbit data rate
- Compatible with ISO 11898-2
- Bus pin fault protection of ±14 V
Integrated 12 kV IEC-61000-4-2 ESD contact discharge protection
- 10 pin headers (IDC cable to DB9)
- One CAN FD transceiver has extra 3-pin screw connector terminal
- Single 3.3V supply
Main Components
- J1. Screw connector terminal of CAN0 bus
- J2. 2.54mm pitch 2x6-pin header Pmod interface
- J3. 2.54mm pitch 2x5-pin box header, CAN0 bus
- J4. 2.54mm pitch 2x5-pin box header, CAN1 bus
- J5. 2.54mm pitch SMT 2x3-pin jumper block, can also be used as CAN1 bus connector
- J6. 2.54mm pitch SMT 2x3-pin jumper block, can also be used as CAN0 bus connector
- U1. Texas Instruments TCAN337G CAN FD transceiver, CAN0
- D1. Bourns CDSOT23-T24CAN CANbus Protector, CAN0
- U2. Texas Instruments TCAN337G CAN FD transceiver, CAN1
- D2. Bourns CDSOT23-T24CAN CANbus Protector, CAN1
Note |
---|
TEP0001 PMOD connector is mounted for Right Angle connection to PMOD Baseboard. |
Interfaces and Pins
J1 Connector, CAN0 Bus
Pin | Signal | Notes |
---|---|---|
1 | CAN0_PH | U1 high level CAN bus line |
2 | GND | U1 ground connection |
3 | CAN0_NL | U1 low level CAN bus line |
J2 Connector, Pmod Interface
Pin | Signal | Notes | Pin | Signal | Notes | |
---|---|---|---|---|---|---|
1 | CAN0_TX | U1 CAN CAN0 transmit data input, integrated pull up | 2 | CAN1_TX | U2 CAN CAN1 transmit data input, integrated pull up | |
3 | CAN0_RX | U1 CAN CAN0 receive data output, tri-state | 4 | CAN1_RX | U2 CAN CAN1 receive data output, tri-state | |
5 | CAN0_S | U1 silent mode,integrated pull down | 6 | CAN1_S | U2 silent mode, integrated pull down | |
7 | CAN0_F | U1 open drain fault output | 8 | CAN1_F | U2 open drain fault output | |
9 | GND | U1 ground connection | 10 | GND | U2 ground connection | |
11 | 3.3V | U1 3.3-V 3V supply voltage | 12 | 3.3V | U2 3.3-V 3V supply voltage |
J3 Connector, CAN0 Bus
Pin | Signal | Notes | Pin | Signal | Notes | |
---|---|---|---|---|---|---|
1 | N/A | - | 2 | GND | U1 ground connection | |
3 | CAN0_NL | U1 low level CAN bus line | 4 | CAN0_PH | U1 high level CAN bus line | |
5 | GND | U1 ground connection | 6 | N/A | - | |
7 | N/A | - | 8 | N/A | - | |
9 | N/A | - | 10 | N/A | - |
J4 Connector, CAN1 Bus
Pin | Signal | Notes | Pin | Signal | Notes | |
---|---|---|---|---|---|---|
1 | N/A | - | 2 | GND | U2 ground connection | |
3 | CAN1_NL | U2 low level CAN bus line | 4 | CAN1_PH | U2 high level CAN bus line | |
5 | GND | U2 ground connection | 6 | N/A | - | |
7 | N/A | - | 8 | N/A | - | |
9 | N/A | - | 10 | N/A | - |
J5 Jumper Block/Connector CAN1 bus
Place jumpers on Close pins 1-3 and 2-4 with jumpers to activate enable on-board CAN bus terminator of U2terminator for CAN1 bus. J5 header can also be used as CAN CAN1 bus connector, refer to the following table below for pin mapping.
Pin | Signal | Note | Pin | Signal | Note | |
---|---|---|---|---|---|---|
3 | CAN1_NL | U2 low level CAN bus line | 4 | CAN1_PH | U2 high level CAN bus line | |
5 | GND | U2 ground connection | 6 | GND | U2 ground connection |
J6 Jumper Block/Connector
...
, CAN0 bus
Close Place jumpers on pins 1-3 and 2-4 with jumpers to activate enable on-board CAN bus terminator of U2. J5 terminator for CAN0 bus. J6 header can also be used as CAN CAN0 bus connector, refer to the following table below for pin mapping.
Pin | Signal | Note | Pin | Signal | Note | |
---|---|---|---|---|---|---|
3 | CAN0_NL | U1 low level CAN bus line | 4 | CAN0_PH | U1 high level CAN bus line | |
5 | GND | U1 ground connection | 6 | GND | U1 ground connection |
Operating Conditions, Ratings and Dimensions
Recommended Operating Conditions
...
Absolute Maximum Ratings
Parameter | Minimum | Maximum | Unit |
---|---|---|---|
Supply voltage range | -0.3 | 5 | V |
Voltage at any bus terminal (CANH or CANL) | -14 | 14 | V |
Operating temperature range | -40 | 150 | °C |
Storage temperature | - | 150 | °C |
Recommended Operating Conditions
Minimum | Maximum | Unit | |
---|---|---|---|
Supply voltage | 3 | 3.6 | V |
Operational free-air temperature | -40 | 125 | °C |
Info |
---|
Refer to Texas Instruments TCAN337G product datasheet for additional information about conditions and ratings. |
...
Module size: 54 mm × 20.5 mm.
Mating height of the J8 J2 connector from the PCB: 8mm
PCB thickness: 1.6mm
Highest part parts on PCB are J1, J2 J3 and J5 J4 connectors, approximately 9.5mm from the PCB.
...
Revision History
...
Date
...
Rrevision
...
Contributors
...
Description
...
Hardware Revision History
Date | Revision | Notes | PCN |
---|---|---|---|
22.08.20162016-08-22 | 01 | Initial batch | - |
Hardware revision number is printed on the PCB board next to the module model number separated by the dash.