TE0630 provides user I/O signals connected to B2B connectors J4 and J5. There are 3 types of user I/O signals:
Single ended;
Differential pairs (each pair is configurable as 2 single-ended digital I/Os);
Differential pairs, which can be used as clock inputs (each pair can be used as usual differential pair or 2 single-ended digital I/Os).
Table 2 show user I/O count for J4 and J5.
|
J4 |
J5 |
Total |
---|---|---|---|
Single ended |
12 |
18 |
30 |
Differential |
18 |
16 |
34 |
Differential (clock) |
4 |
2 |
6 |
Total |
56 |
54 |
110 |
Table 2: User I/O count by connector
Table 3 show user I/O divided by VCCIO supply voltage.
|
VCCIO0 |
3.3V |
Total |
---|---|---|---|
Single ended |
1 |
29 |
30 |
Differential |
18 |
16 |
34 |
Differential (clock) |
4 |
2 |
6 |
Total |
45 |
65 |
110 |
Table 3: User I/O count by VCCIO