CompanyTrenz Electronic GmbH
PCN NumberPCN-20240909
TitleTE0865-02 CPLD Firmware Update / TEBT0865-01 Hardware Patch
SubjectTE0865-02 CPLD Firmware Update / TEBT0865-01 Hardware Patch
Issue Date

2024-09-17

Products Affected

Following boards are affected:

  • Module TE0865-02 with CPLD firmware revision REV03
  • Carrier board TEBT0865-01 with a serial number greater than 860651

Refer to TE0865 CPLD Firmware for TE0865-02 CPLD firmware identification and update.

Changes

#1 CPLD firmware update for TE0865-02 and hardware modification for carrier board TEBT0865-01.

Type: Firmware Update (TE0865-02) and Hardware Modification (TEBT0865-01)

Reason: Firmware improvement.

Impact: Updated module firmware leads to a TE0865-02 power-up deadlock on unpatched baseboards TEBT0865-01 as it is visible in the Compatibility Overview below. To solve this issue, Hardware Patch is applied to TEBT0865-01 with a serial number greater than 860651. If baseboard with lower serial numbers shall support TE0865-02 modules with new firmware, hardware patch needs to be applied. Otherwise, TE0865-02 modules with new firmware will not power up.

Compatibility Overview

Compatibility

Overview

TE0865-02

Firmware Revision

TEBT0865-01

Serial Number

< REV03REV03
< 860651WorkingNOT WORKING
> 860651WorkingWorking

Hardware Patch

Module firmware update leads to a power up deadlock. To fix this issue it is necessary to cut the wire on bottom side between resistor R97 and testpoint TP20 as visible in the following figures.

General:

TEBT0865-01 Bottom Side:


Method of Identification

TE0865-02TEBT0865-01


Production Shipment Schedule

This change takes place with immediate effect. If the new revision is not suitable for your application and still the former revision of the board is needed, please contact us.


Contact Information

If you have any questions related to this PCN, please contact Trenz Electronics Technical Support at

Disclaimer

Any projected dates in this PCN are based on the most current product information at the time this PCN is being issued, but they may change due to unforeseen circumstances.  For the latest schedule and any other information, please contact your local Trenz Electronic sales office, technical support or local distributor.

This PCN follows JEDEC Standard J-STD-046.