Overview
Firmware for system controller with designator U41: 10M08SAU169C8G
Feature Summary
- DCDC Mode Control
- Fan Control
- FMC Voltage Control
- JTAG Control
- LED Control
- UART
- User Button
- Power Management
- Reset Management
Firmware Revision and supported PCB Revision
See Document Change History
Product Specification
Port Description
Name / opt. VHD Name | Direction | Pin | Bank Power | Description |
---|---|---|---|---|
BOOTSEL2 / BOOTSEL2 | out | L10 | +3.3V | Boot Select Bit 2 |
JTAGSEL0 / JTAGSEL0 | in | F9 | +3.3V_MAX10 | Select JTAG Connection |
JTAGSEL1 / JTAGSEL1 | in | E9 | +3.3V_MAX10 | Select JTAG Connection |
FTDI_JTAG_TC/SK / FTDI_TCK | in | G2 | +3.3V_MAX10 | FTDI JTAG TCK |
FTDI_JTAG_TDO/DI / FTDI_TDI | in | F6 | +3.3V_MAX10 | FTDI JTAG TDI |
FTDI_JTAG_TMS/CS / FTDI_TMS | in | G1 | +3.3V_MAX10 | FTDI JTAG TCK |
HPS_TDO / HPS_TDO | in | J6 | +3.3V | HPS JTAG TDO |
FPGA_TDI / FPGA_TDO | in | J1 | +3.3V | FPGA JTAG TDO |
FMC_TDO / FMC_TDO | in | M10 | +3.3V | FMC JTAG TDO |
FTDI_JTAG_TDI/DO / FTDI_TDO | out | F5 | +3.3V_MAX10 | FTDI JTAG TDO |
HPS_TCK / HPS_TCK | out | K1 | +3.3V | HPS JTAG TCK |
HPS_TDI / HPS_TDI | out | M4 | +3.3V | HPS JTAG TDI |
HPS_TMS / HPS_TMS | out | M7 | +3.3V | HPS JTAG TMS |
FPGA_TCK / FPGA_TCK | out | K2 | +3.3V | HPS JTAG TCK |
FPGA_TDO / FPGA_TDI | out | L2 | +3.3V | FPGA JTAG TDI |
FPGA_TMS / FPGA_TMS | out | J2 | +3.3V | FPGA JTAG TMS |
FMC_TCK/ FMC_TCK | out | M8 | +3.3V | FMC JTAG TCK |
FMC_TDI / FMC_TDI | out | M9 | +3.3V | FMC JTAG TDI |
FMC_TMS / FMC_TMS | out | M11 | +3.3V | FMC JTAG TMS |
HPS_RST#_SW / HPS_RSTn_SW | in | J5 | +3.3V | Reset Button |
HPS_RST#_BO / HPS_RSTn_BO | in | K6 | +3.3V | Brown Out Detection |
HPS_WARM_RST#_SW / HPS_WARM_RSTn_SW | in | K5 | +3.3V | Warm Reset Button |
FPGA_RST#_SW / FPGA_RSTn_SW | in | B4 | +3.3V_MAX10 | FPGA Reset Button |
HPS_RST# / HPS_RSTn | out | L11 | +3.3V | HPS Reset |
HPS_WARM_RST# / HPS_WARM_RSTn | out | M3 | +3.3V | HPS Warm Reset |
FPGA_RST# / FPGA_RSTn | out | L13 | VDD_DDR_FPGA | FPGA Reset |
VID0_SW / VID0_SW | in | F8 | +3.3V_MAX10 | Power Selection Pin 0 for FMC Voltage |
VID1_SW / VID1_SW | in | E8 | +3.3V_MAX10 | Power Selection Pin 1 for FMC Voltage |
VID2_SW / VID2_SW | in | D8 | +3.3V_MAX10 | Power Selection Pin 2 for FMC Voltage |
CPU_GPIO_0 / CPU_GPIO0 | in | N10 | +3.3V | CPU GPIO 0 (used for automatic power selection for FMC Voltage) |
CPU_GPIO_1 / CPU_GPIO1 | in | N9 | +3.3V | CPU GPIO 1 (used for automatic power selection for FMC Voltage) |
CPU_GPIO_2 / CPU_GPIO2 | in | N11 | +3.3V | CPU GPIO 2 (used for automatic power selection for FMC Voltage) |
VID0 / VID0 | out | B2 | +3.3V_MAX10 | Power Selection Pin 0 for FMC Voltage at U43 |
VID1 / VID1 | out | C2 | +3.3V_MAX10 | Power Selection Pin 1 for FMC Voltage at U43 |
VID2 / VID2 | out | F4 | +3.3V_MAX10 | Power Selection Pin 2 for FMC Voltage at U43 |
PWR_SEL / PWR_SEL | out | E4 | +3.3V_MAX10 | Power Selection for Cyclone V FMC VCCPD at U37 |
USER_BTN_SW / USER_BTN_SW | in | B3 | +3.3V_MAX10 | User Button |
USER_BTN_FPGA / USER_BTN_FPGA | out | G12 | VDD_DDR_FPGA | FPGA User Button |
BDBUS0 / FTDI_RXD | in | D1 | +3.3V_MAX10 | FTDI UART RXD |
FPGA_GPIO_1 / FPGA_IO1 | in | J10 | VDD_DDR_FPGA | FPGA IO 1 |
FPGA_GPIO_0 / FPGA_IO0 | out | K11 | VDD_DDR_FPGA | FPGA IO 0 |
BDBUS1 / FTDI_TXD | out | C1 | +3.3V_MAX10 | FTDI UART TXD |
CPU_GPIO_4 / CPU_GPIO4 | in | H4 | +3.3V | CPU GPIO 4 (used for fan control) |
FAN_EN / FAN_EN | out | D13 | +3.3V_MAX10 | Fan Control |
MODE_VCC / MODE_DCDC_VCC | out | D9 | +3.3V_MAX10 | VCC DCDC Mode Selection |
MODE / MODE_DCDC_5V | out | A11 | +3.3V_MAX10 | +5.0 V DCDC Mode Selection |
MODE_DDR_FPGA / MODE_DCDC_FPGA | out | E10 | +3.3V_MAX10 | FPGA DDR Power DCDC Mode Selection |
MODE_DDR_HPS / MODE_DCDC_HPS | out | F10 | +3.3V_MAX10 | HPS DDR Power DCDC Mode Selection |
PG_+5.0V / PG_5V0 | in | A8 | +3.3V_MAX10 | +5.0 V Power Good |
PG_VCC / PG_VCC | in | B11 | +3.3V_MAX10 | VCC Power Good |
PG_+2.5V / PG_2V5 | in | C11 | +3.3V_MAX10 | +2.5 V Power Good |
PG_+1.8V / PG_1V8 | in | D11 | +3.3V_MAX10 | +1.8 V Power Good |
PG_+3.3V / PG_3V3 | in | B12 | +3.3V_MAX10 | +3.3 V Power Good |
EN_VCC / EN_VCC | out | A10 | +3.3V_MAX10 | VCC Power Enable |
EN_+2.5V / EN_2V5 | out | A12 | +3.3V_MAX10 | +2.5 V Power Enable |
EN_+1.8V / EN_1V8 | out | D12 | +3.3V_MAX10 | +1.8 V Power Enable |
LED_VCC / LED_VCC | out | F12 | +3.3V_MAX10 | VCC Power Led |
EN_+3.3V / EN_3V3 | out | B13 | +3.3V_MAX10 | +3.3 V Power Enable |
EN_+0.9V / EN_0V9 | out | F1 | +3.3V_MAX10 | +0.9 V Power Enable |
LED_+1.8 V / LED_1V8 | out | H2 | +3.3V_MAX10 | +1.8 V Power Led |
EN_DDR_HPS / EN_DDR_HPS | out | F13 | +3.3V_MAX10 | HPS DDR Power Enable |
EN_DDR_FPGA / EN_DDR_FPGA | out | E13 | +3.3V_MAX10 | FPGA DDR Power Enable |
CPU_GPIO_3 / CPU_GPIO3 | in | L1 | +3.3V | CPU GPIO 3 (used for FMC Power Enable) |
FMC_PRSNT_M2C# / FMC_PRSNT_M2Cn | in | J7 | +3.3V | FMC Card Detection from FMC Connector |
EN_FMC_+12.0V / EN_FMC_12V | out | C12 | +3.3V_MAX10 | +12.0 V FMC Power Enable |
EN_FMC / EN_FMC | out | E1 | +3.3V_MAX10 | Power Enable for FMC Voltage at U43 |
PWR_SWT_EN / PWR_VCCPD_EN | out | C10 | +3.3V_MAX10 | Power Enable for Cyclone V VCCPD Voltage |
EN_FMC_+3.3V / EN_FMC_3V3 | out | C13 | +3.3V_MAX10 | +3.3 V FMC Power Enable |
FMC_PG_C2M / FMC_PG_C2M | out | K7 | +3.3V | FMC Power Good Signal to FMC Connector |
POK_FMC / POK_FMC | in | E3 | +3.3V_MAX10 | Power Good for FMC Voltage at U43 |
PG_VDD_FPGA / PG_VDD_FPGA | in | E12 | +3.3V_MAX10 | FPGA VDD DDR Power Good |
PG_VDD_HPS / PG_VDD_HPS | in | G10 | +3.3V_MAX10 | HPS VDD DDR Power Good |
LED_FMC_VADJ / LED_FMC_VADJ | out | C9 | +3.3V_MAX10 | Power Good Led for FMC Voltage at U43 |
LED_VDD_DDR_FPGA / LED_VDD_DDR_FPGA | out | E6 | +3.3V_MAX10 | FPGA DDR VDD Power Good Led |
LED_VTT_DDR_FPGA / LED_VTT_DDR_FPGA | out | D6 | +3.3V_MAX10 | FPGA DDR VTT Power Good Led |
LED_VDD_DDR_HPS / LED_VDD_DDR_HPS | out | H3 | +3.3V_MAX10 | HPS DDR VDD Power Good Led |
LED_VTT_DDR_HPS / LED_VTT_DDR_HPS | out | G4 | +3.3V_MAX10 | HPS DDR VTT Power Good Led |
JTAGEN / | in | E5 | +3.3V_MAX10 | Select JTAG Connection |
EN_+5.0V / EN_5V0 | out | A7 | +3.3V_MAX10 | +5.0 V Power Enable |
PG_VTT_FPGA / PG_VTT_FPGA | in | B10 | +3.3V_MAX10 | FPGA VTT DDR Power Good |
PG_VTT_HPS / PG_VTT_HPS | in/out | B5 | +3.3V_MAX10 | HPS VTT DDR Power Good |
STATUS / | out | H1 | +3.3V_MAX10 | / currently_not_used |
BDBUS2 / | in/out | B1 | +3.3V_MAX10 | / currently_not_used |
BCBUS2 / | in/out | A9 | +3.3V_MAX10 | / currently_not_used |
DEVCLRn / | ??? | B9 | +3.3V_MAX10 | / currently_not_used |
BDBUS7 / | in/out | A6 | +3.3V_MAX10 | / currently_not_used |
BCBUS1 / | in/out | B6 | +3.3V_MAX10 | / currently_not_used |
BDBUS5 / | in/out | A4 | +3.3V_MAX10 | / currently_not_used |
BDBUS4 / | in/out | A3 | +3.3V_MAX10 | / currently_not_used |
nSTATUS / | in/out | C4 | +3.3V_MAX10 | / currently_not_used |
CONF_DONE / | in/out | C5 | +3.3V_MAX10 | / currently_not_used |
BDBUS3 / | in/out | A2 | +3.3V_MAX10 | / currently_not_used |
BDBUS6 / | in/out | A5 | +3.3V_MAX10 | / currently_not_used |
CLK_MAX10 / | in | H6 | +3.3V | / currently_not_used |
ETH_RST / | out | G5 | +3.3V | / currently_not_used |
USB_RST | out | H5 | +3.3V | / currently_not_used |
USER_BTN_HPS / | out | M2 | +3.3V | / currently_not_used |
nCONFIG_I / | in | M1 | +3.3V | / currently_not_used |
MSEL1 / | in/out | N3 | +3.3V | / currently_not_used |
MSEL2 / | in/out | N2 | +3.3V | / currently_not_used |
USB_HUB_RST / | out | L3 | +3.3V | / currently_not_used |
FPGA_GPIO_9 / | in/out | K10 | VDD_DDR_FPGA | / currently_not_used |
FPGA_GPIO_3 / | in/out | L12 | VDD_DDR_FPGA | / currently_not_used |
FPGA_GPIO_2 / | in/out | K12 | VDD_DDR_FPGA | / currently_not_used |
FPGA_GPIO_11 / | in/out | J12 | VDD_DDR_FPGA | / currently_not_used |
FPGA_GPIO_8 / | in/out | J9 | VDD_DDR_FPGA | / currently_not_used |
FPGA_GPIO_12 / | in/out | H10 | VDD_DDR_FPGA | / currently_not_used |
FPGA_GPIO_10 / | in/out | J13 | VDD_DDR_FPGA | / currently_not_used |
FPGA_GPIO_5 / | in/out | H13 | VDD_DDR_FPGA | / currently_not_used |
FPGA_GPIO_7 / | in/out | H9 | VDD_DDR_FPGA | / currently_not_used |
FPGA_GPIO_6 / | in/out | H8 | VDD_DDR_FPGA | / currently_not_used |
FPGA_GPIO_4 / | in/out | G13 | VDD_DDR_FPGA | / currently_not_used |
nSTATUS_I / | in | L4 | +3.3V | / currently_not_used |
CONF_DONE_I / | in | L5 | +3.3V | / currently_not_used |
HPS_TRST# / | out | M5 | +3.3V | / currently_not_used |
MSEL0 / | out | N5 | +3.3V | / currently_not_used |
MSEL3 / | out | N4 | +3.3V | / currently_not_used |
MSEL4 / | out | N6 | +3.3V | / currently_not_used |
CLKSEL0 / | out | N8 | +3.3V | / currently_not_used |
CLKSEL1 / | out | N7 | +3.3V | / currently_not_used |
FMC_TRST# / | out | M12 | +3.3V | / currently_not_used |
FMC_SDA / | in/out | M13 | +3.3V | / currently_not_used |
HPS_SPI_SS/BOOTSEL0 | in/out | K8 | +3.3V | / currently_not_used |
QSPI_CS/BOOTSEL1 | in/out | J8 | +3.3V | / currently_not_used |
FMC_SCL / | in/out | N12 | +3.3V | / currently_not_used |
Functional Description
DCDC Mode Control
The mode signals are connected to "1".
Signal | State | Description |
---|---|---|
MODE_DCDC_VCC, MODE_DCDC_5V | 1 | Forced Continous Mode |
0 | Discontinous Mode | |
MODE_DCDC_FPGA, MODE_DCDC_HPS | 1 | Pulse-Skipping Mode for VDD |
0 | Forced Continous Mode for VDD |
Fan Control
Can be enabled/disabled through the Intel Cyclone V HPS "CPU_GPIO4".
FMC Voltage Control
The power is enabled if signal "CPU_GPIO3" is set to "1" and there is an FMC card. Then, the +12.0 V level is enabled. After that, the adjustable voltage is enabled. Finally, the +3.3 V level is enabled. Then, the signal "FMC_PG_C2M" is asserted.
JTAG Control
The FTDI JTAG is connected to the Intel MAX10, the Intel Cyclone V HPS and Fabric and to the FMC Connector according to the following table.
JTAG_SEL0 | JTAG_SEL1 | JTAGEN | JTAG Connection |
---|---|---|---|
X | X | 1 - (ON) | Intel MAX10 |
0 - (ON) | 0 - (ON) | 0 - (OFF) | Cyclone V HPS |
0 - (ON) | 1 - (OFF) | 0 - (OFF) | Cyclone V FPGA |
1 - (OFF) | 0 - (ON) | 0 - (OFF) | FMC |
LED Control
The leds signals their power good status.
UART
The second channel of the JTAG FTDI interface delievers an UART connection to the Intel Cyclone V fabric.
User Button
The User Button is connected to the FPGA.
Power Management
The power sequencing is handled inside the system controller according to the next figure.
The FMC power sequencing depends on the assertion through the signals "CPU_GPIO3" and "FMC_PRSNT_M2Cn". If both of them are asserted, the +12.0 V level starts, followed by the adjustabel voltage level with the according pre-driver voltage and finally, the +3.3 V level is started.
The FMC adjustable voltage selection can be done manually by the switches or automatically by the Intel Cyclone V HPS. The choice is done via the switches according to the next table. The voltage for the Intel Cyclone V HPS pre-driver is selected according to the voltage setting.
S8-C | S8-B | S8-A | Voltage | Setting |
---|---|---|---|---|
ON | ON | ON | 3.3 V | Manual |
ON | ON | OFF | 2.5 V | Manual |
ON | OFF | ON | 1.8 V | Manual |
ON | OFF | OFF | 1.5 V | Manual |
OFF | ON | ON | 1.25 V | Manual |
OFF | ON | OFF | 1.2 V | Manual |
OFF | OFF | ON | 0.8 V | Manual |
OFF | OFF | OFF | CPU-dependent | CPU |
Reset Management
The reset buttons are connected via the system controller to the according reset locations. That means that, if the reset button S1 or the brown-out detection is asserted, the Cyclone V should be reseted. If the warm reset button S3 is asserted, the Cyclone V should be warm reseted. If the FPGA reset button S4 is asserted, the FPGA could be reseted.
Appx. A: Change History and Legal Notices
Revision Changes
CPLD REV01 to REV02
- Changed pin connections
- Changed JTAG connection
- Changed reset connection
- Changed FMC Vadj Voltage selection
- Changed power sequencing
Document Change History
To get content of older revision got to "Change History" of this page and select older document revision number.
Date | Document Revision | CPLD Firmware Revision | Supported PCB Revision | Authors | Description |
---|---|---|---|---|---|
Work in progress | |||||
2020-02-19 | REV02 | REV02 | Initial release | ||
All |
Legal Notices
Data Privacy
Please also note our data protection declaration at https://www.trenz-electronic.de/en/Data-protection-Privacy
Document Warranty
The material contained in this document is provided “as is” and is subject to being changed at any time without notice. Trenz Electronic does not warrant the accuracy and completeness of the materials in this document. Further, to the maximum extent permitted by applicable law, Trenz Electronic disclaims all warranties, either express or implied, with regard to this document and any information contained herein, including but not limited to the implied warranties of merchantability, fitness for a particular purpose or non infringement of intellectual property. Trenz Electronic shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein.
Limitation of Liability
In no event will Trenz Electronic, its suppliers, or other third parties mentioned in this document be liable for any damages whatsoever (including, without limitation, those resulting from lost profits, lost data or business interruption) arising out of the use, inability to use, or the results of use of this document, any documents linked to this document, or the materials or information contained at any or all such documents. If your use of the materials or information from this document results in the need for servicing, repair or correction of equipment or data, you assume all costs thereof.
Copyright Notice
No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Trenz Electronic.
Technology Licenses
The hardware / firmware / software described in this document are furnished under a license and may be used /modified / copied only in accordance with the terms of such license.
Environmental Protection
To confront directly with the responsibility toward the environment, the global community and eventually also oneself. Such a resolution should be integral part not only of everybody's life. Also enterprises shall be conscious of their social responsibility and contribute to the preservation of our common living space. That is why Trenz Electronic invests in the protection of our Environment.
REACH, RoHS and WEEE
REACH
Trenz Electronic is a manufacturer and a distributor of electronic products. It is therefore a so called downstream user in the sense of REACH. The products we supply to you are solely non-chemical products (goods). Moreover and under normal and reasonably foreseeable circumstances of application, the goods supplied to you shall not release any substance. For that, Trenz Electronic is obliged to neither register nor to provide safety data sheet. According to present knowledge and to best of our knowledge, no SVHC (Substances of Very High Concern) on the Candidate List are contained in our products. Furthermore, we will immediately and unsolicited inform our customers in compliance with REACH - Article 33 if any substance present in our goods (above a concentration of 0,1 % weight by weight) will be classified as SVHC by the European Chemicals Agency (ECHA).
RoHS
Trenz Electronic GmbH herewith declares that all its products are developed, manufactured and distributed RoHS compliant.
WEEE
Information for users within the European Union in accordance with Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment (WEEE).
Users of electrical and electronic equipment in private households are required not to dispose of waste electrical and electronic equipment as unsorted municipal waste and to collect such waste electrical and electronic equipment separately. By the 13 August 2005, Member States shall have ensured that systems are set up allowing final holders and distributors to return waste electrical and electronic equipment at least free of charge. Member States shall ensure the availability and accessibility of the necessary collection facilities. Separate collection is the precondition to ensure specific treatment and recycling of waste electrical and electronic equipment and is necessary to achieve the chosen level of protection of human health and the environment in the European Union. Consumers have to actively contribute to the success of such collection and the return of waste electrical and electronic equipment. Presence of hazardous substances in electrical and electronic equipment results in potential effects on the environment and human health. The symbol consisting of the crossed-out wheeled bin indicates separate collection for waste electrical and electronic equipment.
Trenz Electronic is registered under WEEE-Reg.-Nr. DE97922676.