If there is a LED directly connected to lower MIO Bank of the Zynq then this LED is also always controllable, as this Bank has to be powered for the device to boot. This LED can also be controlled if the PL portion of the Zynq is not configured or even un-powered.
VIO LED
LED's on TE SoM's and Baseboards
MIO LED | DONE LED | User LED PL | Notes | |
---|---|---|---|---|
TE0710 | - | |||
TE0711 | - | |||
TE0712 | - | No* | Yes* | LED's are routed to PL I/O by System Control CPLD |
TE0714 | - | No | Yes | One fixed LED on PL,1.8V or 3.3V I/O Voltage always present |
TE0720 | MIO7 | Yes, Fixed | Yes* | System control CPLD can remap the LED functions during FSBL |
TE0725 | - | Yes | Yes | LED's power always available |
Base | User LED's | Notes | |
---|---|---|---|
TE0701 | |||
TE0703 | 2* | User supplied I/O Voltage | |
...