You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »


Table of contents

Overview

TEI0006 firmware for Intel MAX 10 FPGA U18: 10M08SAU169C8G

Feature Summary

  • JTAG routing
  • UART routing
  • LED control
  • Power control
  • Reset
  • Configuration mode selection

Firmware Revision and supported PCB Revision

See Document Change History

Product Specification

Port Description

Name / opt. VHD NameDirectionPinBank PowerDescription

BASE_BTN1

inC93.3VUser button "USER_BTN1" from carrier board TEIB0006 (B2B connector → J2-152)
BASE_BTN2inB33.3VUser button "USER_BTN2" from carrier board TEIB0006 (B2B connector → J2-154)
BASE_LED1outA63.3VLed "LED1" from carrier board TEIB0006 (B2B connector → J2-146)
BASE_LED2outA33.3VLed "LED2" from carrier board TEIB0006 (B2B connector → J2-148)
DATA0inN51.8VIOData input from Intel Cyclone 10 GX → Pin AE10
DEVCLRnoutJ51.8VIODevice-wide reset, Intel Cyclone 10 GX → Pin AC12
DIS_1outK123.3VFast Discharging - connected to GND
DIS_2outK103.3VFast Discharging - connected to GND
DIS_3outJ93.3VFast Discharging - connected to GND
DIS_4outJ123.3VFast Discharging - connected to GND
EN_0V9outE93.3VPower enable signal 0.9V
EN_0V95outJ103.3VPower enable signal  0.95V
EN_1V8outD93.3VPower enable signal 1.8V
EN_1V8MBoutH93.3VPower enable signal 1.8V for carrier board TEIB0006 (B2B connector → J2-86)
EN_1V8VIOoutL123.3VPower enable signal 1.8V IO
EN_1V35outD123.3VPower enable signal 1.35V
EN_3V3MBoutA113.3VPower enable signal 3.3V for carrier board TEIB0006 (B2B connector → J2-74)
EN_VTToutC113.3VPower enable signal VTT
LED1outB123.3Vstatus led, red led D1
LED2outB113.3Vgreen led D2 /currently unused - connected to GND
LED3outA123.3Vuser defined, green led D3
LED4outB123.3Vuser defined, green led D4
MSEL0outM71.8VIOconfiguration mode selection
MSEL1outM91.8VIOconfiguration mode selection
PG_0V9inE103.3VPower Good signal 0.9V
PG_0V95inH103.3VPower Good signal 0.95V
PG_1V8inF83.3VPower Good signal 1.8V
PLL_RSToutL31.8VIOClock reset, SI5345A
RXD_INinN61.8VIOUART, Intel Cyclone 10 GX
TXD_OUToutK51.8VIOUART, Intel Cyclone 10 GX
RXD_OUToutA103.3VUART, B2B connector
TXD_INinB103.3VUART, B2B connector
TCK_INinG23.3VJTAG, B2B connector → J2-157
TDI_INinF53.3VJTAG, B2B connector → J2-159
TDO_OUToutF63.3VJTAG, B2B connector → J2-158
TMS_INinG13.3VJTAG, B2B connector → J2-160
TCK_OUToutN21.8VIOJTAG, Intel Cyclone 10 GX
TDI_OUToutM21.8VIOJTAG, Intel Cyclone 10 GX
TDO_INinM31.8VIOJTAG, Intel Cyclone 10 GX
TMS_OUToutK11.8VIOJTAG, Intel Cyclone 10 GX
nCONFIGoutM81.8VIOFPGA configuration pin, Intel Cyclone 10 GX
nSTATUSinM51.8VIOFPGA configuration pin, Intel Cyclone 10 GX


Functional Description

JTAG

JTAG signals are routed directly from B2B connector through Intel MAX 10 to Intel Cyclone 10 GX. Access between Intel MAX 10 and Intel Cyclone 10 GX can be multiplexed via JTAGEN. JTAGEN pin is already pulled up to 3.3V for access to Intel MAX 10, for access to Intel Cyclone 10 GX JTAGEN pin has to pulled down to GND on B2B connector J2-105.

With carrier board TEIB0006:

DIP Switch S1-1 position = OFF → access to Intel MAX 10

                                           ON → access to Intel Cyclone 10 GX

UART

UART signals are routed directly from B2B connector through Intel MAX 10 to Intel Cyclone 10 GX.

B2BIntel MAX 10Intel Cyclone 10 GX
MAX_IO17 | J2-151A10 | RXD_OUT ← RXD_IN | N6AA12
MAX_IO18 | J2-153B10 | TXD_IN → TXD_OUT | K5AC11

LED control

BASE_LED1 (B2B connector → J2-146) and the nCONFIG Pin from Intel Cyclone 10 GX are connected to user button BASE_BTN1 (B2B connector → J2-152).

BASE_LED2 (B2B connector → J2-148) is connected to user button BASE_BTN2 (B2B connector → J2-154).

LED1 is connected to nSTATUS pin from Intel Cyclone 10 GX.

LED2 is connected to GND.

LED3 and LED4 are connected to DATA0 pin from Intel Cyclone 10 GX.

Power control

EN_0V9 is set constant to logical one and enables power regulator U4 for 0.9V.

If power good signal PG_0V9 from power regulator U4 is set to logical one, output pin EN_0V95 is set to logical one and enables power regulator U7 for 0.95V.

If power good signal PG_0V95 from power regulator U4 is set to logical one, output pin EN_1V8 is set to logical one and enables power regulator U5 for 1.8V.

If power good signal PG_1V8 from power regulator U4 is set to logical one,

  • output pin EN_1V8VIO is set to logical one and enables power regulator U6 for 1.8VIO,
  • output pin EN_3V3MB is set to logical one  (connnected to J2-74 → enables power regulator U3 on carrier board TEIB0006),
  • output pin EN_1V8MB is set to logical one (connected to J2-86 → enables power regulator U12 on carrier board TEIB0006),
  • output pin EN_1V35 is set to logical one and enables power regulator U8 for 1.35V (VDD_DDR),
  • output pin EN_VTT is set to logical one and enables power regulator U9 for VTT_DDR.

Reset

DEVCLRn (Device-wide reset) and clock reset PLL_RST for SI5345A are set constant to logical one.

Configuration mode selection

MSEL0 and MSEL1 are set constant to logical one. The selected configuration mode is "AS / Standard".

Appx. A: Change History and Legal Notices

Revision Changes

Document Change History

To get content of older revision  got to "Change History"  of this page and select older document revision number.

DateDocument RevisionCPLD Firmware RevisionSupported PCB RevisionAuthorsDescription

Error rendering macro 'page-info'

Ambiguous method overloading for method jdk.proxy279.$Proxy4022#hasContentLevelPermission. Cannot resolve which method to invoke for [null, class java.lang.String, class com.atlassian.confluence.pages.Page] due to overlapping prototypes between: [interface com.atlassian.confluence.user.ConfluenceUser, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject] [interface com.atlassian.user.User, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject]

Error rendering macro 'page-info'

Ambiguous method overloading for method jdk.proxy279.$Proxy4022#hasContentLevelPermission. Cannot resolve which method to invoke for [null, class java.lang.String, class com.atlassian.confluence.pages.Page] due to overlapping prototypes between: [interface com.atlassian.confluence.user.ConfluenceUser, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject] [interface com.atlassian.user.User, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject]

REV1REV1

Error rendering macro 'page-info'

Ambiguous method overloading for method jdk.proxy279.$Proxy4022#hasContentLevelPermission. Cannot resolve which method to invoke for [null, class java.lang.String, class com.atlassian.confluence.pages.Page] due to overlapping prototypes between: [interface com.atlassian.confluence.user.ConfluenceUser, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject] [interface com.atlassian.user.User, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject]

Initial release

All

Error rendering macro 'page-info'

Ambiguous method overloading for method jdk.proxy279.$Proxy4022#hasContentLevelPermission. Cannot resolve which method to invoke for [null, class java.lang.String, class com.atlassian.confluence.pages.Page] due to overlapping prototypes between: [interface com.atlassian.confluence.user.ConfluenceUser, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject] [interface com.atlassian.user.User, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject]


Legal Notices

Data Privacy

Please also note our data protection declaration at https://www.trenz-electronic.de/en/Data-protection-Privacy

Document Warranty

The material contained in this document is provided “as is” and is subject to being changed at any time without notice. Trenz Electronic does not warrant the accuracy and completeness of the materials in this document. Further, to the maximum extent permitted by applicable law, Trenz Electronic disclaims all warranties, either express or implied, with regard to this document and any information contained herein, including but not limited to the implied warranties of merchantability, fitness for a particular purpose or non infringement of intellectual property. Trenz Electronic shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein.

Limitation of Liability

In no event will Trenz Electronic, its suppliers, or other third parties mentioned in this document be liable for any damages whatsoever (including, without limitation, those resulting from lost profits, lost data or business interruption) arising out of the use, inability to use, or the results of use of this document, any documents linked to this document, or the materials or information contained at any or all such documents. If your use of the materials or information from this document results in the need for servicing, repair or correction of equipment or data, you assume all costs thereof.

Copyright Notice

No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Trenz Electronic.

Technology Licenses

The hardware / firmware / software described in this document are furnished under a license and may be used /modified / copied only in accordance with the terms of such license.

Environmental Protection

To confront directly with the responsibility toward the environment, the global community and eventually also oneself. Such a resolution should be integral part not only of everybody's life. Also enterprises shall be conscious of their social responsibility and contribute to the preservation of our common living space. That is why Trenz Electronic invests in the protection of our Environment.

REACH, RoHS and WEEE

REACH

Trenz Electronic is a manufacturer and a distributor of electronic products. It is therefore a so called downstream user in the sense of REACH. The products we supply to you are solely non-chemical products (goods). Moreover and under normal and reasonably foreseeable circumstances of application, the goods supplied to you shall not release any substance. For that, Trenz Electronic is obliged to neither register nor to provide safety data sheet. According to present knowledge and to best of our knowledge, no SVHC (Substances of Very High Concern) on the Candidate List are contained in our products. Furthermore, we will immediately and unsolicited inform our customers in compliance with REACH - Article 33 if any substance present in our goods (above a concentration of 0,1 % weight by weight) will be classified as SVHC by the European Chemicals Agency (ECHA).

RoHS

Trenz Electronic GmbH herewith declares that all its products are developed, manufactured and distributed RoHS compliant.

WEEE

Information for users within the European Union in accordance with Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment (WEEE).

Users of electrical and electronic equipment in private households are required not to dispose of waste electrical and electronic equipment as unsorted municipal waste and to collect such waste electrical and electronic equipment separately. By the 13 August 2005, Member States shall have ensured that systems are set up allowing final holders and distributors to return waste electrical and electronic equipment at least free of charge. Member States shall ensure the availability and accessibility of the necessary collection facilities. Separate collection is the precondition to ensure specific treatment and recycling of waste electrical and electronic equipment and is necessary to achieve the chosen level of protection of human health and the environment in the European Union. Consumers have to actively contribute to the success of such collection and the return of waste electrical and electronic equipment. Presence of hazardous substances in electrical and electronic equipment results in potential effects on the environment and human health. The symbol consisting of the crossed-out wheeled bin indicates separate collection for waste electrical and electronic equipment.

Trenz Electronic is registered under WEEE-Reg.-Nr. DE97922676.


Error rendering macro 'page-info'

Ambiguous method overloading for method jdk.proxy279.$Proxy4022#hasContentLevelPermission. Cannot resolve which method to invoke for [null, class java.lang.String, class com.atlassian.confluence.pages.Page] due to overlapping prototypes between: [interface com.atlassian.confluence.user.ConfluenceUser, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject] [interface com.atlassian.user.User, class java.lang.String, class com.atlassian.confluence.core.ContentEntityObject]





  • No labels